- AX50-30-00-75
The ABB AX50-30-00-75 is an AC contactor with three main poles (3 NO, 0 NC) and no auxiliary contacts. It measures 82 mm wide, 110 mm deep, and 108 mm high, weighing 1.05 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 100 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 45 A at 440 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 25 kW at 415 V and 30 kW at 690 V. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX50-30-00-80
The ABB AX50-30-00-80 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 °C. AC-3 ratings include 50 A at 415 V and 35 A at 690 V, both at 55 °C. The coil operates at 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX50-30-00-81
The ABB AX50-30-00-81 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. The conventional free-air thermal current is 100 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 50 A at 415 V and 55 °C, and 35 A at 690 V and 55 °C. AC-3 rated operational power is 25 kW at 415 V and 30 kW at 690 V. The control circuit voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg.
- AX50-30-00-83
The ABB AX50-30-00-83 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 53 A at 220/230/240 V, 45 A at 440 V and 500 V, and 35 A at 690 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V, 25 kW at 415 V and 440 V, and 30 kW at 500 V and 690 V. Coil voltage is 48 V at 50 Hz and 60 Hz. Terminals are screw type. Maximum operating altitude without derating is 3000 m.
- AX50-30-00-84
The ABB AX50-30-00-84 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a 690 V main and auxiliary circuit at 50/60 Hz, with a conventional free-air thermal current of 100 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 50 A at 415 V and 55 °C, and rated operational power is 22 kW at 380/400 V. Maximum electrical switching frequency is 600 cycles per hour in AC-1 and AC-3; maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX50-30-00-85
The ABB AX50-30-00-85 is an AC-operated contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. The conventional free-air thermal current (Ith) is 100 A at 40 °C according to IEC 60947-4-1. Rated operational current AC-3 is 50 A at 415 V and 55 °C, and rated operational power AC-3 is 25 kW at 415 V. The rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. The contactor uses screw terminals and has dimensions of 70 mm width, 110 mm depth, and 108 mm height, with a net weight of 1.01 kg.
- AX50-30-00-86
ABB AX50-30-00-86 AC contactor, manufacturer ID 1SBL351074R8600. Three-pole (3 NO main contacts, 0 NC), block-type, screw terminals. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage: 400 to 415 V at 50 Hz, 415 to 440 V at 60 Hz. Conventional free-air thermal current 100 A per IEC 60947-4-1 at 40 °C, open contactors. AC-3 ratings include 50 A at 415 V and 35 A at 690 V, both at 55 °C, with corresponding rated operational power of 25 kW at 415 V and 30 kW at 690 V. Dimensions 70 mm wide, 110 mm deep, 108 mm high; net weight 1.01 kg. Coil terminals IP20, main terminals IP10 per IEC 60529.
- AX50-30-00-88
The ABB AX50-30-00-88 is an AC contactor with three main contacts, normally open, and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 degrees C. Rated operational current AC-3 is 50 A at 415 V and 55 degrees C. Screw terminals are used, with main terminals rated IP10 and coil terminals IP20 according to IEC 60529.