- AX06-30-01-86
The ABB AX06-30-01-86 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 7 A at 415 V, 440 V, 500 V, and 380/400 V, and 5 A at 690 V, at 55 °C. Rated operational power AC-3 is 3 kW at 415 V and 4 kW at 690 V. The coil is rated 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Screw terminals, IP20 coil terminals, dimensions 44 mm width, 74 mm depth, 74 mm height, 0.326 kg.
- AX06-30-01-88
The ABB AX06-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 20 A at 220/240 V (55 °C); AC-3 is 7 A at 415 V (55 °C), corresponding to 3 kW. Coil voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Connection is via screw terminals, coil terminals IP20 per IEC 60529.
- AX06-30-10-26
ABB AC contactor AX06-30-10-26, manufacturer ID 1SBL891074R2610. It has three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 22 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 7 A at 415 V, 440 V, 500 V, and 380/400 V, and 5 A at 690 V, all at 55 °C. Rated operational power AC-3 is 3 kW at 415 V and 4 kW at 690 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg.
- AX06-30-10-36
ABB AX06-30-10-36 AC contactor, manufacturer ID 1SBL891074R3610. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50 / 60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 7 A at 415 V, 55 °C. Rated control circuit voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Terminals are screw type; coil terminals are IP20 per IEC 60529. Maximum operating altitude without derating is 3000 m.
- AX06-30-10-75
ABB AC contactor, model AX06-30-10-75, manufacturer ID 1SBL891074R7510. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1, both at 40 °C. Rated operational current AC-3 is 7 A at 415 V and 55 °C, and 5 A at 690 V and 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg.
- AX06-30-10-80
ABB AX06-30-10-80 AC contactor, manufacturer ID 1SBL891074R8010. Three main contacts NO, no main contacts NC, plus one auxiliary contact NO. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Coil control voltage 50 Hz 220 to 230 V, 60 Hz 230 to 240 V. Rated operational current AC-1: 20 A at 220/240 V and 55 °C, 20 A at 690 V and 40 °C, 16 A at 690 V and 70 °C. Rated operational current AC-3: 7 A at 415 V and 55 °C, 5 A at 690 V and 55 °C. Rated operational power AC-3: 3 kW at 415 V, 1.5 kW at 220/230/240 V. Screw terminals, IP20 coil terminals, dimensions 44 x 74 x 74 mm, 0.326 kg.
- AX06-30-10-81
The ABB AX06-30-10-81 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. The coil is rated 24 V at 50 Hz and 24 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C, and AC-1 rated operational current is 20 A at 690 V and 40 °C. AC-3 ratings include 7 A at 415 V and 3 kW at 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminals are screw type, and the coil terminals are rated IP20 per IEC 60529.
- AX06-30-10-83
ABB AC contactor AX06-30-10-83 (manufacturer ID 1SBL891074R8310). It has three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage is 48 V at 50 Hz and 48 V at 60 Hz. Conventional free-air thermal current is 22 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 7 A at 415 V and 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type, coil terminals IP20 per IEC 60529.