- AX06-30-01-88
The ABB AX06-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 20 A at 220/240 V (55 °C); AC-3 is 7 A at 415 V (55 °C), corresponding to 3 kW. Coil voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Connection is via screw terminals, coil terminals IP20 per IEC 60529.
- AX06-30-10-26
ABB AC contactor AX06-30-10-26, manufacturer ID 1SBL891074R2610. It has three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 22 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 7 A at 415 V, 440 V, 500 V, and 380/400 V, and 5 A at 690 V, all at 55 °C. Rated operational power AC-3 is 3 kW at 415 V and 4 kW at 690 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg.
- AX06-30-10-36
ABB AX06-30-10-36 AC contactor, manufacturer ID 1SBL891074R3610. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50 / 60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 7 A at 415 V, 55 °C. Rated control circuit voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Terminals are screw type; coil terminals are IP20 per IEC 60529. Maximum operating altitude without derating is 3000 m.
- AX06-30-10-75
ABB AC contactor, model AX06-30-10-75, manufacturer ID 1SBL891074R7510. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 22 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1, both at 40 °C. Rated operational current AC-3 is 7 A at 415 V and 55 °C, and 5 A at 690 V and 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg.
- AX06-30-10-80
ABB AX06-30-10-80 AC contactor, manufacturer ID 1SBL891074R8010. Three main contacts NO, no main contacts NC, plus one auxiliary contact NO. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Coil control voltage 50 Hz 220 to 230 V, 60 Hz 230 to 240 V. Rated operational current AC-1: 20 A at 220/240 V and 55 °C, 20 A at 690 V and 40 °C, 16 A at 690 V and 70 °C. Rated operational current AC-3: 7 A at 415 V and 55 °C, 5 A at 690 V and 55 °C. Rated operational power AC-3: 3 kW at 415 V, 1.5 kW at 220/230/240 V. Screw terminals, IP20 coil terminals, dimensions 44 x 74 x 74 mm, 0.326 kg.
- AX06-30-10-81
The ABB AX06-30-10-81 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. The coil is rated 24 V at 50 Hz and 24 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits. Conventional free-air thermal current is 22 A per IEC 60947-4-1 at 40 °C, and AC-1 rated operational current is 20 A at 690 V and 40 °C. AC-3 ratings include 7 A at 415 V and 3 kW at 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminals are screw type, and the coil terminals are rated IP20 per IEC 60529.
- AX06-30-10-83
ABB AC contactor AX06-30-10-83 (manufacturer ID 1SBL891074R8310). It has three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage is 48 V at 50 Hz and 48 V at 60 Hz. Conventional free-air thermal current is 22 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 7 A at 415 V and 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type, coil terminals IP20 per IEC 60529.
- AX06-30-10-85
The ABB AX06-30-10-85 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. The rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. Conventional free-air thermal current is 22 A according to IEC 60947-4-1 at 40 degrees C. Rated operational current AC-3 is 7 A at 380/400 V and 415 V at 55 degrees C. Screw terminals are used. Coil terminals are rated IP20 according to IEC 60529.