- AX40-30-12-81
The ABB AX40-30-12-81 is an AC contactor with a block-type design, three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 66 mm wide, 108 mm deep, and 90 mm high, and weighs 0.715 kg. Maximum operating altitude is 3000 m without derating. Manufacturer ID: 1SBL321074R8112.
- AX40-30-21-81
ABB AC contactor, model AX40-30-21-81, manufacturer ID 1SBL321074R8121. It has three normally open main contacts and three auxiliary contacts (two normally open, one normally closed). Dimensions are 66 mm wide, 108 mm deep, and 90 mm high, with a net weight of 0.715 kg. Maximum operating altitude is 3000 m without derating. ETIM classification: EC000066 - Power contactor, AC switching. The reference text mentions a conflicting identifier and claims about voltage, frequency, and standards that are not present in the supplied technical parameters; those details are omitted.
- AX50-30-00-26
The ABB AX50-30-00-26 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 50 A at 415 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 25 kW at 415 V and 30 kW at 690 V. Maximum mechanical switching frequency is 3600 cycles per hour. Manufacturer ID: 1SBL351074R2600.
- AX50-30-00-36
The ABB AX50-30-00-36 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 45 A at 440 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 690 V. The contactor uses screw terminals, has a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and a rated impulse withstand voltage of 6 kV for the auxiliary circuit. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX50-30-00-75
The ABB AX50-30-00-75 is an AC contactor with three main poles (3 NO, 0 NC) and no auxiliary contacts. It measures 82 mm wide, 110 mm deep, and 108 mm high, weighing 1.05 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 100 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 50 A at 415 V and 55 °C, 45 A at 440 V and 55 °C, and 35 A at 690 V and 55 °C. Rated operational power AC-3 is 25 kW at 415 V and 30 kW at 690 V. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX50-30-00-80
The ABB AX50-30-00-80 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 100 A according to IEC 60947-4-1 at 40 °C. AC-3 ratings include 50 A at 415 V and 35 A at 690 V, both at 55 °C. The coil operates at 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX50-30-00-81
The ABB AX50-30-00-81 is a block-type AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. The conventional free-air thermal current is 100 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 50 A at 415 V and 55 °C, and 35 A at 690 V and 55 °C. AC-3 rated operational power is 25 kW at 415 V and 30 kW at 690 V. The control circuit voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg.
- AX50-30-00-83
The ABB AX50-30-00-83 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 50 A at 380/400 V and 415 V, 53 A at 220/230/240 V, 45 A at 440 V and 500 V, and 35 A at 690 V, all at 55 °C. Rated operational power AC-3 is 22 kW at 380/400 V, 25 kW at 415 V and 440 V, and 30 kW at 500 V and 690 V. Coil voltage is 48 V at 50 Hz and 60 Hz. Terminals are screw type. Maximum operating altitude without derating is 3000 m.