Industrial Automation Parts. Prompt replies from real people.

ABB AX18-30-01-83 Contactors

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AX18-30-01-83?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AX18-30-01-83 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AX18-30-01-83
Material Number
1SBL921074R8301
Manufacturer
ABB
Product ID
74029

Get a Free Quote

Request pricing and availability for AX18-30-01-83.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.326 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A (690 V) 40 °C 27 A (690 V) 70 °C 20 A
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
See all specifications

Product Highlights

  1. Main Contacts: 3 NO and 0 NC
  2. Auxiliary Contacts: 0 NO and 1 NC
  3. Coil Voltage: 48 V at 50 Hz and 60 Hz
  4. Rated Operational Voltage: 690 V for both main and auxiliary circuits
  5. Rated Frequency: 50 / 60 Hz for both main and auxiliary circuits
  6. Conventional Free-air Thermal Current (Ith): 28 A per IEC 60947-4-1 for open contactors at 40 °C and 16 A per IEC 60947-5-1 at 40 °C
  7. Rated Operational Current AC-1 (Ie): 25 A at 220 / 240 V and 55 °C, 27 A at 690 V and 40 °C, 20 A at 690 V and 70 °C
  8. Rated Operational Current AC-3 (Ie): 18 A at 415 V and 55 °C, 12 A at 440 V and 55 °C, 12 A at 500 V and 55 °C, 9 A at 690 V and 55 °C, 18 A at 380 / 400 V and 55 °C, 18 A at 220 / 230 / 240 V and 55 °C
  9. Rated Operational Power AC-3 (Pe): 9 kW at 415 V, 5.5 kW at 440 V, 7.5 kW at 500 V, 7.5 kW at 690 V, 7.5 kW at 380 / 400 V, 4 kW at 220 / 230 / 240 V
  10. Rated Operational Current AC-15 (Ie): 6 A at 24 / 127 V, 4 A at 220 / 240 V, 3 A at 380 / 400 V, 2 A at 400 / 440 V, 2 A at 500 V, 2 A at 690 V
  11. Rated Operational Current DC-13 (Ie): 6 A / 144 W at 24 V, 1.1 A / 121 W at 110 V, 1.1 A / 138 W at 125 V, 0.55 A / 121 W at 220 V, 0.55 A / 138 W at 250 V, 2.8 A / 134 W at 400 V, 2 A / 144 W at 500 V
  12. Rated Short-time Withstand Current (Icw): 300 A for 1 s, 145 A for 10 s, 80 A for 30 s, 60 A for 1 min, 28 A for 15 min at 40 °C in free air from a cold state
  13. Maximum Breaking Capacity: 250 A at 440 V and 90 A at 690 V with cos phi 0.45
  14. Maximum Electrical Switching Frequency: 600 cycles per hour in AC-1, 1200 cycles per hour in AC-3 and AC-15, 900 cycles per hour in DC-13
  15. Maximum Mechanical Switching Frequency: 3600 cycles per hour
  16. Operate Time: 10 to 26 ms coil energization to NO contact closing, 4 to 11 ms coil de-energization to NO contact opening, 7 to 21 ms coil energization to NC contact opening, 9 to 16 ms coil de-energization to NC contact closing
  17. Rated Insulation Voltage (Ui): 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C)
  18. Rated Impulse Withstand Voltage (Uimp): 6 kV for auxiliary circuit
  19. Degree of Protection: IP20 for main, auxiliary, and coil terminals per IEC 60529, IEC 60947-1, EN 60529
  20. Terminal Type: Screw terminals
  21. General Use Rating UL/CSA: 30 A at 600 V AC
  22. Horsepower Rating UL/CSA: 1 hp at 120 V AC single phase, 3 hp at 240 V AC single phase, 5 hp at 200 to 240 V AC three phase, 10 hp at 440 to 480 V AC three phase, 15 hp at 550 to 600 V AC three phase
  23. Tightening Torque UL/CSA: 9 in·lb for main, auxiliary, and control circuits
  24. Ambient Air Temperature: -40 to 70 °C for operation in free air and without thermal O/L relay, -25 to 55 °C close to contactor with thermal O/L relay, -60 to +80 °C for storage
  25. Maximum Operating Altitude: 3000 m without derating
  26. Product Net Dimensions: 44 mm width, 74 mm depth, 74 mm height
  27. Product Net Weight: 0.326 kg
AX18-30-01-83

Product Information

Technical Specifications

Specifications for AX18-30-01-83

ParameterValue
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height74 mm
Product Net Weight0.326 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 25 A (690 V) 40 °C 27 A (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 18 A (440 V) 55 °C 12 A (500 V) 55 °C 12 A (690 V) 55 °C 9 A (380400 V) 55 °C 18 A (220230240 V) 55 °C 18 A
Rated Operational Power AC-3 (Pe)(415 V) 9 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW (380400 V) 7.5 kW (220230240 V) 4 kW
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (380400 V) 3 A (400440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-15) 1200 cycles per hour (AC-3) 1200 cycles per hour (DC-13) 900 cycles per hour
ParameterValue
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (110 V) 1.1 A121 W (125 V) 1.1 A138 W (220 V) 0.55 A121 W (250 V) 0.55 A138 W (400 V) 2.8 A134 W (500 V) 2 A144 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 48 V 60 Hz 48 V
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal TypeScrew Terminals
General Use Rating UL/CSA(600 V AC) 30 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 1 hp (200 ... 208 V AC) Three Phase 5 hp (220 ... 240 V AC) Three Phase 5 hp (240 V AC) Single Phase 3 hp (440 ... 480 V AC) Three Phase 10 hp (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 9 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL921074R8301

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp