- NSIN0900-6 (IP00)
ABB NSIN0900-6 (IP00) is listed as a frequency converter option, manufacturer ID 3ABD64254961. The IP00 designation indicates an enclosure without ingress protection. The unit has a net weight of 690 kg and net dimensions of 1000 mm width, 640 mm depth, and 2120 mm height. Frame size is given as ACS140_option. UNSPSC classification is 39122005. No electrical ratings, input or output voltage, current, frequency, or operating temperature range are supplied, so those parameters cannot be stated. The available data covers identity, physical dimensions, mass, frame size, and classification only.
- NSL22E-81
The ABB NSL22E-81 is an intermediate relay with screw terminals and DIN rail mounting. It has 2 NO and 2 NC auxiliary contacts. The rated control circuit voltage is 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. It measures 45 mm wide, 72.5 mm deep, and 68 mm high, weighing 0.28 kg. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14. Maximum mechanical switching frequency is 3600 cycles per hour. Operating ambient air temperature near the contactor in free air is -40 to 70 °C.
- NSL22ES-81
The ABB NSL22ES-81 is an intermediate relay with 2 NO and 2 NC auxiliary contacts and spring terminals. Its coil operates at 24 V DC. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high, with a net weight of 0.28 kg. The relay is rated 690 V in the auxiliary and main circuits, at 50/60 Hz in the auxiliary circuit, with a conventional free-air thermal current of 10 A according to IEC 60947-5-1 at 40 °C. It conforms to IEC 60947-5-1, EN 60947-5-1, UL 508, and CSA C22.2 N°14. Auxiliary and coil terminals are IP20. Operating ambient air temperature near the contactor in free air is -40 to 70 °C.
- NSL31E-81 24VDC
ABB NSL31E-81 24VDC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC + NO x3, and Control voltage: 24V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NSL31ES-81
ABB intermediate relay NSL31ES-81, manufacturer ID 1SBH103004R8131. Auxiliary contact configuration is 3 NO and 1 NC. Rated control circuit voltage is 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits; rated frequency for the auxiliary circuit is 50/60 Hz. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage for the auxiliary circuit is 6 kV. Terminals are spring type, with 10 mm wire stripping length. Dimensions are 45 mm width, 72.5 mm depth/length, and 68 mm height; net weight is 0.28 kg. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL40E-81
ABB NSL40E-81 intermediate relay, manufacturer ID 1SBH103001R8140. It has four normally open auxiliary contacts and no normally closed contacts, with screw terminals. The control circuit is rated 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz for the auxiliary circuit. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V and 2 A at 690 V. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high; net weight 0.28 kg. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL40ES-81
The ABB NSL40ES-81 is an intermediate relay with four normally open (NO) auxiliary contacts and no normally closed contacts. It operates on a 24 V DC control circuit voltage and uses spring terminals. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high, with a net weight of 0.28 kg. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Conventional free-air thermal current is 10 A at 40 °C per IEC 60947-5-1. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13); maximum mechanical switching frequency is 3600 cycles per hour. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL44ES-81
ABB intermediate relay NSL44ES-81, manufacturer ID 1SBH103004R8144. It has 4 NO and 4 NC auxiliary contacts and spring terminals. The control circuit is rated 24 V DC. Dimensions are 45 mm wide, 110.7 mm deep, and 68 mm high, with a net weight of 0.32 kg. The conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 Group C, and 600 V per UL/CSA. Rated impulse withstand voltage for the auxiliary circuit is 6 kV. Applicable standards are IEC 60947-5-1 and EN 60947-5-1, UL 508, and CSA C22.2 No. 14. Auxiliary and coil terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.