- NSL40E-81
ABB NSL40E-81 intermediate relay, manufacturer ID 1SBH103001R8140. It has four normally open auxiliary contacts and no normally closed contacts, with screw terminals. The control circuit is rated 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz for the auxiliary circuit. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V and 2 A at 690 V. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high; net weight 0.28 kg. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL40ES-81
The ABB NSL40ES-81 is an intermediate relay with four normally open (NO) auxiliary contacts and no normally closed contacts. It operates on a 24 V DC control circuit voltage and uses spring terminals. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high, with a net weight of 0.28 kg. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Conventional free-air thermal current is 10 A at 40 °C per IEC 60947-5-1. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13); maximum mechanical switching frequency is 3600 cycles per hour. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL44ES-81
ABB intermediate relay NSL44ES-81, manufacturer ID 1SBH103004R8144. It has 4 NO and 4 NC auxiliary contacts and spring terminals. The control circuit is rated 24 V DC. Dimensions are 45 mm wide, 110.7 mm deep, and 68 mm high, with a net weight of 0.32 kg. The conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 Group C, and 600 V per UL/CSA. Rated impulse withstand voltage for the auxiliary circuit is 6 kV. Applicable standards are IEC 60947-5-1 and EN 60947-5-1, UL 508, and CSA C22.2 No. 14. Auxiliary and coil terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- NSL53E-81
ABB NSL53E-81 intermediate relay (contactor relay), manufacturer ID 1SBH103001R8153. It has 5 NO and 3 NC auxiliary contacts, a rated control circuit voltage of 24 V DC, and a rated frequency of 50/60 Hz for the auxiliary circuit. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 10 A per IEC 60947-5-1 at 40 °C. Dimensions are 45 mm width, 100.2 mm depth, and 68 mm height, with a net weight of 0.32 kg. Screw terminals accept 0.75 to 2.5 mm² conductors with 9 mm stripping length. Standards: IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL53ES-81
ABB NSL53ES-81 intermediate relay with spring terminals, 5 NO and 3 NC auxiliary contacts. Rated control circuit voltage is 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz in the auxiliary circuit. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 45 mm wide, 110.7 mm deep, and 68 mm high; net weight 0.32 kg. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14. Manufacturer ID 1SBH103004R8153.
- NSL62E-81
ABB NSL62E-81 intermediate relay, manufacturer ID 1SBH103001R8162. It has 6 NO and 2 NC auxiliary contacts. Control circuit voltage is 24 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits; rated frequency for the auxiliary circuit is 50/60 Hz. Conventional free-air thermal current is 10 A at 40 °C per IEC 60947-5-1. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Dimensions are 45 mm wide, 100.2 mm deep, and 68 mm high; net weight 0.32 kg. Screw terminals accept 0.75 to 2.5 mm² conductors with 9 mm stripping length. Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14.
- NSL62ES-81
The ABB NSL62ES-81 intermediate relay has a 24 V DC control circuit voltage and six normally open plus two normally closed auxiliary contacts. It is rated 690 V in the auxiliary and main circuits, with a rated frequency of 50/60 Hz in the auxiliary circuit, and a conventional free-air thermal current of 10 A at 40 °C according to IEC 60947-5-1. Maximum electrical switching frequency is 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13. Spring terminals accept rigid and flexible conductors from 0.75 to 2.5 mm², with 10 mm stripping length. Dimensions are 45 mm wide, 110.7 mm deep, and 68 mm high; net weight is 0.32 kg. Standards include IEC 60947-5-1 and EN 60947-5-1, UL 508, and CSA C22.2 N°14.
- NSL80E-81
ABB NSL80E-81 intermediate relay, manufacturer ID 1SBH103001R8180. It has 8 normally open auxiliary contacts and no normally closed contacts, with a rated control circuit voltage of 24 V DC. Dimensions are 45 mm wide, 100.2 mm deep, and 68 mm high, weighing 0.32 kg. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage for the auxiliary circuit is 6 kV. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 degrees C. Standards include IEC 60947-5-1, EN 60947-5-1, UL 508, and CSA C22.2 No. 14. Terminals are screw type with IP20 protection.