Product Model
NSL62ES-81
Material Number
1SBH103004R8162
Manufacturer
ABB
Product ID
69986

Get a Free Quote

Request pricing and availability for NSL62ES-81.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.32 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Contact Configuration: 6 NO and 2 NC auxiliary contacts
  2. Coil and Switching Ratings: 24 V DC control coil, 690 V rated operational voltage for auxiliary and main circuits, 50/60 Hz auxiliary circuit frequency, and 10 A conventional free-air thermal current (Ith) at 40 °C per IEC 60947-5-1
  3. Utilization Category Ratings: AC-15 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, 2 A at 500 V and 690 V, DC-13 6 A/144 W at 24 V, 2.8 A/134 W at 48 V, 1 A/72 W at 72 V, 0.55 A/60 W at 110 V, 0.55 A/69 W at 125 V, 0.27 A/60 W at 220 V, 0.27 A/68 W at 250 V
  4. Switching Frequency and Withstand: 1200 cycles per hour AC-15, 900 cycles per hour DC-13, 3600 cycles per hour mechanical, and short-time withstand current of 140 A for 0.1 s and 100 A for 1 s
  5. Terminals and Protection: Spring terminals with 0.75 to 2.5 mm² rigid or flexible-with-ferrule connecting capacity, 10 mm wire stripping length, and IP20 protection on auxiliary and coil terminals
  6. Operating Conditions: -40 to +70 °C ambient air temperature in free air, 3000 m maximum operating altitude without derating, and shock and vibration resistance per IEC 60068-2-27
  7. Standards and Dimensions: IEC 60947-5-1, EN 60947-5-1, UL 508, and CSA C22.2 No. 14, 45 mm width, 110.7 mm depth, 68 mm height, 0.32 kg net weight
NSL62ES-81

Product Information

Technical Specifications

Specifications for NSL62ES-81

ParameterValue
Product Net Width45 mm
Product Net Depth / Length110.7 mm
Product Net Height68 mm
Product Net Weight0.32 kg
Number of Auxiliary Contacts NO6
Number of Auxiliary Contacts NC2
StandardsIEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (400440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
ParameterValue
Rated Control Circuit Voltage (Uc)DC Operation 24 V
Operate TimeBetween Coil De-energization and NC Contact Closing 15 ... 20 ms Between Coil De-energization and NO Contact Opening 13 ... 17 ms Between Coil Energization and NC Contact Opening 31 ... 53 ms Between Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeSpring Terminals
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 20 g Closed, Shock Direction: B1 15 g Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 14 g Open, Shock Direction: A 10 g Open, Shock Direction: B1 5 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 8 g Shock Direction: B2 10 g
Resistance to Vibrations3g Closed Position & 2g Open Position 5 ... 300 Hz
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
Manufacturer ID1SBH103004R8162

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB NSL62ES-81 | Reliable 24VDC Relay for Efficient Control