- CA4X-10
ABB auxiliary contact block, model CA4X-10, manufacturer ID 1SBN011310R1010. It provides 1 normally open (NO) auxiliary contact and 0 normally closed (NC) contacts. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high, with a net weight of 0.014 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Standards: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5. Auxiliary terminals are IP20.
- CA4X-11
ABB auxiliary contact block, display model CA4X-11, manufacturer ID 1SBN011310R1011. It provides one normally open and one normally closed auxiliary contact, side mounting, with auxiliary circuit rated operational voltage 690 V at 50/60 Hz. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V to IEC 60947-5-1 and VDE 0110 (Gr. C), 600 V to UL/CSA; rated impulse withstand voltage is 6 kV. Auxiliary terminals are IP20 to IEC 60529. Dimensions: 43 mm width, 19.9 mm depth, 23.6 mm height; net weight 0.024 kg.
- CA4X-20
ABB auxiliary contact block, model CA4X-20, manufacturer ID 1SBN011310R1020. It provides two normally open (NO) auxiliary contacts and no normally closed (NC) contacts. Dimensions are 43 mm width, 19.9 mm depth, 23.6 mm height, and 0.024 kg net weight. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 10 A according to IEC 60947-5-1 at 40 °C ambient. Rated operational current is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V under AC-15. Standards listed: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5. Auxiliary terminals are IP20.
- CA5-01
ABB CA5-01 auxiliary contact block, manufacturer ID 1SBN010010R1001. It is a front-mounted, 1-pole auxiliary contact block with screw terminals, one normally closed (NC) instantaneous contact, and no normally open (NO) contacts. Dimensions are 11 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.014 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with AC-15 ratings of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Mechanical durability is 10 million cycles. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- CA5-01-AU FASTON
ABB CA5-01-AU FASTON auxiliary contact block, manufacturer ID 1SBN010014R9002. This front-mounted, 1-pole block has flat-pin (FASTON) terminals and one instantaneous normally open (N.O.) gold-flashed contact. Dimensions are 11 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.02 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Suitable for A9 A12 A16 A26 A30 A40 A45 A50 A63 A75 A95 A110 AL9 AL12 AL16 AL26 AL30 AL40 AE45 AE50 AE63 AE75 TAL9 TAL12 TAL16 TAL26 TAL30 TAL40 TAE45 TAE50 TAE75. ETIM class EC000041.
- CA5-04E
ABB CA5-04E auxiliary contact block, manufacturer ID 1SBN010040R1004. It provides four normally closed (NC) auxiliary contacts and no normally open (NO) contacts, with screw terminals. Dimensions are 43 mm width, 39 mm depth/length, and 47 mm height; net weight 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with AC-15 rated operational current of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 2.8 A / 134 W at 48 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- CA5-04M
The ABB CA5-04M is a front-mount auxiliary contact block with four normally closed (NC) auxiliary contacts and no normally open (NO) contacts. It uses screw terminals and measures 43 mm wide, 39 mm deep, and 47 mm high, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V and 50/60 Hz, with AC-15 ratings of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Mechanical durability is 10 million operations. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Suitable for A9 through A40, AL9 through AL40, TAL9 through TAL40, and UA16 through UA30.
- CA5-04N
ABB CA5-04N auxiliary contact block, manufacturer ID 1SBN010040R1204. Front-mount block with 4 normally closed (NC) auxiliary contacts and 0 normally open (NO) contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Mechanical durability is 10 million operations; maximum mechanical switching frequency is 3600 cycles per hour. Dimensions: 43 mm width, 39 mm depth, 47 mm height; net weight 0.06 kg. Screw terminals, IP20 at auxiliary terminals. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.