- B6-30-01-P-02
ABB B6-30-01-P-02 is a three-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V (40 °C and 55 °C), and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 42 V AC. Mechanical durability is 10,000,000 cycles. Terminals are IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail to IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-P-03
The ABB B6-30-01-P-03 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The rated control circuit voltage is 48 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C according to IEC 60947-4-1. Rated operational power AC-3 is 4 kW at 400 V three-phase and 2.2 kW at 230 V three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-30-01-P-1.4-72
ABB B6-30-01-P-1.4-72 is an interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. The main circuit is rated 690 V AC and 220 V DC, with a rated insulation voltage of 690 V and a rated impulse withstand voltage of 6 kV for both main and auxiliary circuits. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is rated 28 V AC. Terminals are IP20. Mechanical durability is 10,000,000 cycles. Net dimensions are 47.5 mm width, 45.2 mm height, and 47.7 mm depth; net weight is 0.17 kg.
- B6-30-01-P-80
The ABB B6-30-01-P-80 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. The rated control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Rated operational power AC-3 is 4 kW at 400 V three-phase and 2.2 kW at 230 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, with a net weight of 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-30-01-P-84
ABB B6-30-01-P-84 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power in AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight is 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and carries IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-P-85
ABB B6-30-01-P-85 mini contactor with 3 NO main poles and 1 NC auxiliary contact. Rated control circuit voltage is 380 to 415 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, weighing 0.17 kg. Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-10-01
ABB B6-30-10-01 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated control circuit voltage is 24 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, with rated operational current AC-1 of 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.175 kg. Mechanical durability is 10,000,000 cycles.
- B6-30-10-02
ABB B6-30-10-02 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Control circuit voltage is 42 V AC. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.175 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.