- B6-30-01-P-1.4-72
ABB B6-30-01-P-1.4-72 is an interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. The main circuit is rated 690 V AC and 220 V DC, with a rated insulation voltage of 690 V and a rated impulse withstand voltage of 6 kV for both main and auxiliary circuits. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is rated 28 V AC. Terminals are IP20. Mechanical durability is 10,000,000 cycles. Net dimensions are 47.5 mm width, 45.2 mm height, and 47.7 mm depth; net weight is 0.17 kg.
- B6-30-01-P-80
The ABB B6-30-01-P-80 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. The rated control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Rated operational power AC-3 is 4 kW at 400 V three-phase and 2.2 kW at 230 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, with a net weight of 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-30-01-P-84
ABB B6-30-01-P-84 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power in AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight is 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and carries IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-P-85
ABB B6-30-01-P-85 mini contactor with 3 NO main poles and 1 NC auxiliary contact. Rated control circuit voltage is 380 to 415 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, weighing 0.17 kg. Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-10-01
ABB B6-30-10-01 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated control circuit voltage is 24 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, with rated operational current AC-1 of 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.175 kg. Mechanical durability is 10,000,000 cycles.
- B6-30-10-02
ABB B6-30-10-02 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Control circuit voltage is 42 V AC. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.175 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-10-03
ABB B6-30-10-03 mini contactor, manufacturer ID GJL1211001R0103. Three-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational power AC-3 is 4 kW at 400 V three-phase, 2.2 kW at 230 V three-phase, and 3 kW at 690 V three-phase. Rated control circuit voltage is 48 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Terminal protection IP20. Mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B6-30-10-14
The ABB B6-30-10-14 is a 3-pole mini contactor with 3 normally open main contacts and 1 normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. Rated operational voltage is 690 V AC for main and auxiliary circuits and 220 V DC for the main circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three phase. Control circuit voltage is 12 V AC. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -25 to +55 °C.