- B6-30-10-84
The ABB B6-30-10-84 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its control circuit is rated 110 to 127 V AC, and the coil operates within 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational power in AC-3 is 4 kW at 400 V three-phase and 2.2 kW at 230 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.175 kg. Terminals are IP20 and accept rigid conductors from 1 to 4 mm². Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-30-10-85
ABB mini contactor B6-30-10-85, manufacturer ID GJL1211001R8105. Three-pole AC contactor with 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO. Rated control circuit voltage 380 to 415 V AC. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Dimensions 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Screw terminals, DIN rail mounting per IEC 60715, IP20 terminals.
- B6-30-10-F-01
The ABB B6-30-10-F-01 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 24 V AC; coil operating limits are 0.85 to 1.1 times Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V three-phase and 4 kW at 400 V or 500 V three-phase. Terminal degree of protection is IP20. Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail according to IEC 60715. Operation is rated -25 to +55 °C.
- B6-30-10-F-02
The ABB B6-30-10-F-02 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The rated control circuit voltage is 42 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Mechanical durability is 10,000,000 cycles. Terminals are IP20 and mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-30-10-F-03
ABB B6-30-10-F-03 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated control circuit voltage is 48 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Main circuit rated operational voltage is 690 V AC, rated insulation voltage 690 V, and rated impulse withstand voltage 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715.
- B6-30-10-F-80
ABB B6-30-10-F-80 AC contactor, 3-pole mini contactor with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage is 690 V AC for the main circuit and 690 V AC / 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Control circuit voltage is 220 to 240 V AC. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth, 0.17 kg net weight. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- B6-30-10-F-84
ABB B6-30-10-F-84 miniature AC contactor, manufacturer ID GJL1211003R8104. Three-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Rated control circuit voltage 110 to 127 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage 690 V; rated impulse withstand voltage 6 kV main and auxiliary circuits. Dimensions 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Ambient operating temperature -25 to +55 °C.
- B6-30-10-F-85
ABB B6-30-10-F-85 mini contactor, manufacturer ID GJL1211003R8105. Three-pole device with three NO main contacts, one NO auxiliary contact, and screw terminals. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Rated insulation voltage 690 V, rated impulse withstand voltage 6 kV. Dimensions 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operating temperature -25 to +55 °C.