- DS201 M C25 A100
The ABB DS201 M C25 A100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 25 A with a 100 mA Type A residual current trip and C tripping characteristic. It is rated 240 V AC according to IEC 60898-1 and complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. Power loss averages 4.1 W per pole. It mounts on DIN rail in any position, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C25 A30
ABB DS201 M C25 A30 leakage protection circuit breaker, Type A residual current, C tripping characteristic, 25 A rated current, 30 mA rated residual current. Two-pole device with one protected pole, DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity 15 kA; rated service short-circuit breaking capacity 11.2 kA. Standards: IEC 61009-1 and IEC 61009-2-1. Screw terminals, connecting capacity 0.75 to 25 mm², tightening torque 2.8 N·m. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M C25 A30 110V
ABB DS201 M C25 A30 110V is a two-pole leakage protection circuit breaker with one protected pole, C tripping characteristic, and Type A residual current. Rated current is 25 A, rated residual current 30 mA, rated operational voltage 240 V AC per IEC 60898-1, and test voltage 110 V. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA, and rated residual breaking capacity 6000 A per EN 61009-1 and IEC 61009-1. It conforms to IEC 61009-1 and IEC 61009-2-1. DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, 200 g. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.
- DS201 M C25 A300
The ABB DS201 M C25 A300 is a 1P+N leakage protection circuit breaker with a rated current of 25 A and a rated residual current of 300 mA, Type A. It has a C tripping characteristic and a rated short-circuit capacity of 10 kA, with a rated ultimate short-circuit breaking capacity (Icu) of 15 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, and rated frequency is 50 to 60 Hz. The device is compliant with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Operating ambient air temperature range is -25 to 55 degrees C. The manufacturer ID is 2CSR275180R3254.
- DS201 M C25 AC100
The ABB DS201 M C25 AC100 is a 1P+N RCBO with a C tripping characteristic and Type AC residual current detection. It is rated 25 A with a 100 mA rated residual current and operates at 50 to 60 Hz. Rated operational voltage is 240 V according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two modular spacings on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C25 AC30
The ABB DS201 M C25 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 25 A and a rated residual current of 30 mA, Type AC. It has a C tripping characteristic and a rated short-circuit capacity of 10 kA, with an Icu of 15 kA and Ics of 11.2 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, and rated frequency is 50 to 60 Hz. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. It uses screw terminals with 2.8 N·m tightening torque and operates from -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M C25 AC300
ABB DS201 M C25 AC300 is a 1P+N leakage protection circuit breaker with two poles and one protected pole, rated 25 A with a 300 mA Type AC residual current and C tripping characteristic. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The rated short-circuit capacity is 10 kA, the rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and the rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, 200 g net weight, and an operating ambient air temperature range of -25 to 55 degrees C.
- DS201 M C25 APR100
The ABB DS201 M C25 APR100 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 25 A and rated residual current of 100 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated ultimate short-circuit breaking capacity is 15 kA; rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C.