- DS201 M C25 APR100
The ABB DS201 M C25 APR100 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 25 A and rated residual current of 100 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated ultimate short-circuit breaking capacity is 15 kA; rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C25 APR30
The ABB DS201 M C25 APR30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It has a rated current of 25 A, rated residual current of 30 mA, and rated short-circuit capacity of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Operating ambient temperature range is -25 to 55 degrees C.
- DS201 M C25 APR300
The ABB DS201 M C25 APR300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 25 A, 300 mA Type A residual current, and C tripping characteristic. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated ultimate short-circuit breaking capacity (Icu) 15 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Screw terminals accept conductors from 0.75 to 25 mm², with 12 mm stripping length and 2.8 N·m tightening torque. Dimensions are 35 mm width, 85 mm height, 69 mm depth; weight 200 g.
- DS201 M C25 G30
ABB DS201 M C25 G30 leakage protection circuit breaker, manufacturer ID 2CSR275482R1254. Rated current 25 A, rated residual current 30 mA, tripping characteristic C, residual current Type A/G, one protected pole in a two-pole device. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M C25 G300
ABB DS201 M C25 G300 leakage protection circuit breaker, manufacturer ID 2CSR275482R3254. Rated current 25 A, rated residual current 300 mA, tripping characteristic C, residual current Type A/G. Two poles, one protected pole, two modular spacings. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity 15 kA; rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. DIN-rail mounting, screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Dimensions 35 mm width, 85 mm height, 69 mm depth; weight 200 g. Ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M C32 AC100
The ABB DS201 M C32 AC100 is a two-module residual current circuit breaker (RCBO) combining overcurrent and earth fault protection in one device. It is rated 32 A with a C tripping characteristic and 100 mA Type AC residual current. Rated operational voltage is 240 V AC per IEC 60898-1, rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, and rated service short-circuit breaking capacity (Ics) 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has one protected pole, two poles total, DIN-rail mounting, screw terminals, 2.8 N·m tightening torque, and dimensions 35 mm by 85 mm by 69 mm.
- DS201 M C32 AC30
The ABB DS201 M C32 AC30 is a leakage protection circuit breaker with a rated current of 32 A and a rated residual current of 30 mA. It has a C tripping characteristic and Type AC residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, weighing 200 g.
- DS201 M C32 AC300
ABB DS201 M C32 AC300 leakage protection circuit breaker, manufacturer ID 2CSR275080R3324. It is a 1P+N RCBO with one protected pole and two poles total, rated 32 A, 300 mA residual current, Type AC, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA, and rated conditional short-circuit current 15 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two module widths, 35 mm wide, 85 mm high, 69 mm deep, 200 g, IP20/IP40, operating ambient air temperature -25 to 55 °C.