Product Model
OT100F4N2
Material Number
1SCA105018R1001
Manufacturer
ABB
Product ID
70675

Get a Free Quote

Request pricing and availability for OT100F4N2.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.49 kg
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 37 kW (500 V) 37 kW (690 V) 37 kW
See all specifications

Product Highlights

  1. Front-Protected Clamp Terminals: Front-protected clamp terminals for secure connections and reduced risk of electrical shock
  2. Non-Fusible Design: Non-fusible disconnection without fuses
  3. Front Operation: Front-operated switch-disconnector
  4. Mounting: Base mounting
  5. Rated Current: Maximum current rating 100 A
  6. Power Rating: 37 kW power rating
  7. Standards and Certifications: Complies with IEC 60947-3, UL 98 and CSA C22.2 NO.4
  8. RoHS Compliance: Follows EU RoHS regulations
  9. Degree of Protection: Front IP20
  10. Number of Poles: 4 poles
  11. Fourth Pole: Switched, simultaneous function, right side
  12. Mechanical Durability: 20000 operations
OT100F4N2

Product Information

Technical Specifications

Specifications for OT100F4N2

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301264D0201
Pollution Degree3
Product Net Width96.5 mm
Product Net Height100 mm
Product Net Depth / Length74 mm
Product Net Weight0.49 kg
Cable Cross-SectionCu 10 ... 70 mm²
Connecting Capacity Main CircuitFlexible 1x Cu 10…70 mm² Stranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 115 A
Conventional Thermal Current (Ithe)Fully Enclosed 115 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeKnob Handle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles4
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 4.0 W
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 100 A (500 V) 100 A (690 V) 100 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 100 A (500 V) 100 A (690 V) 100 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 80 A (500 V) 60 A (690 V) 40 A
ParameterValue
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 22 kW (400 ... 415 V) 37 kW (500 V) 37 kW (690 V) 37 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 2.5 kA
Recommended Screw DriverMain Circuit Hexagon 4
Special FunctionsNo
StandardsIEC 60947-3UL 98CSA C22.2 NO.4
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 6 N·m
Wire Stripping LengthMain Circuit 18-21 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating100 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 5 Hp (240 V AC) Single Phase 15 Hp (440 ... 480 V AC) Single Phase 25 Hp (550 ... 600 V AC) Single Phase 20 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 50 Hp (550 ... 600 V AC) Three Phase 50 Hp
Wire Stripping LengthMain Circuit 18-21 mm
Recommended Screw DriverMain Circuit Hexagon 4
Tightening Torqueacc. IEC 60947-1 6 N·m
Tightening Torque UL/CSA55 in·lb
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601403
E-Number (Norway)4363531
E-Number (Sweden)3171073
Manufacturer ID1SCA105018R1001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.