Q1Can you supply the ABB OT100G2-3BS?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT100G2-3BS cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT100G2-3BS
Material Number
1SCA162547R1001
Manufacturer
ABB
Product ID
90216

Get a Free Quote

Request pricing and availability for OT100G2-3BS.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.251 kg
Rated Conditional Short-Circuit Current (Inc)
(100 A fuse, ≤415 V) 5 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC 60947-1 800 V
Rated Operational Power AC-23A (Pe)
(415 V) 45 kW (690 V) 37 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 3-pole isolating switch rated 100 A (Ith/Ithe), 800 V insulation voltage, 8 kV impulse withstand, and operational current of 100 A at 415 V or 80 A at 690 V for AC-21A and AC-22A
  2. Switching Capacity: AC-23A rating of 80 A at 415 V and 40 A at 690 V, with 45 kW at 415 V and 37 kW at 690 V operational power
  3. Short-Circuit Withstand: Conditional short-circuit current of 5 kA with a 100 A fuse at up to 415 V and 50 kA with an 80 A fuse at 690 V, plus 1.5 kA for 1 s and 2.5 kA for 0.2 s short-time withstand
  4. Connection and Mounting: Screw terminals accept 1.5 to 35 mm² flexible or stranded copper, tightening torque 2 N·m, wire stripping length 13 to 16 mm, and base or DIN-rail mounting
  5. Operating Mechanism and Protection: Front-operated knob handle with lockable design, mechanism on top of the switch, front IP20 protection, and pollution degree 3
  6. Durability and Compliance: Mechanical durability of 100,000 operations, 5.3 W power loss per pole at rated conditions, and compliance with IEC 60947-3, UL 60947-4-1, and CSA C22.2 No.14
OT100G2-3BS

Product Information

Technical Specifications

Specifications for OT100G2-3BS

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301333D0201
Pollution Degree3
Product Net Width52.5 mm
Product Net Height91.5 mm
Product Net Depth / Length73 mm
Product Net Weight0.251 kg
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x Cu 1.5…4 mm² Solid 1/2x Cu 1.5…6 mm² Flexible 1x Cu 1.5…35 mm² Flexible 2x Cu 1.5…16 mm² Stranded 1x Cu 1.5…35 mm² Stranded 2x Cu 1.5…16 mm²
Conventional Free-air Thermal Current (Ith)100 A
Conventional Thermal Current (Ithe)100 A
Degree of ProtectionFront IP20
Handle ColorBlack
Handle Length37 mm
Handle TypeKnob Handle External handle and shaft not included
Lock TypeYes
Maximum Mounted Auxiliary Contacts4 NO, 4 NC
Mechanical DurabilityNr. Operations 100000
Mounting TypeBase/DIN mounting
Number of Poles3P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 5.3 W
Rated Conditional Short-Circuit Current (Inc)(100 A fuse, ≤415 V) 5 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC 60947-1 800 V
ParameterValue
Rated Operational Current AC-21A (Ie)(415 V) 100 A (690 V) 80 A
Rated Operational Current AC-22A (Ie)(415 V) 100 A (690 V) 80 A
Rated Operational Current AC-23A (Ie)(415 V) 80 A (690 V) 40 A
Rated Operational Power AC-23A (Pe)(415 V) 45 kW (690 V) 37 kW
Rated Operational VoltageMain Circuit 800 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.5 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1.5 kA for 0.2 s 2.5 kA
Recommended Screw DriverMain Circuit Pozidriv 2
Special FunctionsNo
StandardsIEC60947-3 UL60947-4-1 CSA C22.2 No.14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 2 N·m
Wire Stripping LengthMain Circuit 13-16 mm Main Circuit 0.51-0.63 in
Maximum Operating Voltage UL/CSA600 V
Wire Size1x 16-2 AWG 2x 16-8 AWG
Wire Stripping LengthMain Circuit 13-16 mm Main Circuit 0.51-0.63 in
Recommended Screw DriverMain Circuit Pozidriv 2
Tightening Torqueacc. IEC 60947-1 2 N·m
Tightening Torque UL/CSAUL 18 lbf·in
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID1SCA162547R1001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB OT100G2-3BS SmartLink Switch Disconnector - Reliable and Efficient