- DS201 M B13 F30
ABB DS201 M B13 F30 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 13 A, rated residual current of 30 mA, Type F residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g.
- DS201 M B16 A100
ABB DS201 M B16 A100 is a 1P+N leakage protection circuit breaker with B tripping characteristic and Type A residual current. Rated current is 16 A; rated residual current is 100 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA; rated ultimate short-circuit breaking capacity is 15 kA. Rated frequency is 50 to 60 Hz. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M B16 A30
The ABB DS201 M B16 A30 is a leakage protection circuit breaker with a rated current of 16 A and rated residual current of 30 mA. It has a B tripping characteristic and Type A residual current sensitivity. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, and occupies two modular spacings for DIN-rail mounting. Dimensions are 85 mm height, 69 mm depth, and 35 mm width, with a net weight of 200 g. Operating ambient air temperature range is -25 to 55 degrees C.
- DS201 M B16 A30 110V
ABB DS201 M B16 A30 110V leakage protection circuit breaker, 1P+N, with B tripping characteristic and Type A residual current detection. Rated current 16 A, rated residual current 30 mA, rated operational voltage 240 V AC per IEC 60898-1, rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Standards: IEC 61009-1 and IEC 61009-2-1. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20 and IP40.
- DS201 M B16 A300
ABB DS201 M B16 A300 is a DIN-rail mounted leakage protection circuit breaker (RCBO) with a B tripping characteristic and Type A residual current detection. It has a rated current of 16 A and a rated residual current of 300 mA, rated operational voltage 240 V AC per IEC 60898-1, rated frequency 50 to 60 Hz, and rated short-circuit capacity of 10 kA. It provides one protected pole in a two-pole, two-module device measuring 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque is 2.8 N·m. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M B16 AC100
ABB DS201 M B16 AC100 leakage protection circuit breaker with a B tripping characteristic and Type AC residual current. Rated current is 16 A and rated residual current is 100 mA. Rated operational voltage is 240 V according to IEC 60898-1. The device is rated 50 to 60 Hz and has a rated short-circuit capacity of 10 kA, rated ultimate short-circuit breaking capacity of 15 kA, and rated service short-circuit breaking capacity of 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, DIN-rail mounting, screw terminals, IP20 protection, and dimensions of 35 mm width, 85 mm height, and 69 mm depth.
- DS201 M B16 AC30
ABB DS201 M B16 AC30 is a 1P+N leakage protection circuit breaker (RCBO) with B tripping characteristic and Type AC residual current. Rated current is 16 A; rated residual current is 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1; rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, has two poles, two modular spacings, screw terminals, and operates from -25 to 55 °C.
- DS201 M B16 F10
ABB DS201 M B16 F10 leakage protection circuit breaker, manufacturer ID 2CSR275580R0165. Two-pole device with one protected pole, rated current 16 A, rated residual current 10 mA, Type F residual current, and B tripping characteristic. Rated operational voltage 240 V AC according to IEC 60898-1; rated insulation voltage 500 V according to IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20 and IP40.