- DS201 C6 AC100
The ABB DS201 C6 AC100 is a 1P+N leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 100 mA, Type AC. It provides overcurrent and earth fault protection. Tripping characteristic is C. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail with two modular spacings, measuring 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 C6 AC30
The ABB DS201 C6 AC30 is a 1P+N RCBO for single-phase circuits, providing overload, short-circuit, and earth fault protection. It has a rated current of 6 A, a rated residual current of 30 mA, Type AC residual current, and C tripping characteristic. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g.
- DS201 C6 APR100
The ABB DS201 C6 APR100 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 6 A, rated residual current of 100 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is rated 50 to 60 Hz, has 2 poles with 1 protected pole, and mounts on DIN rail. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 C6 APR30
The ABB DS201 C6 APR30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 6 A with a 30 mA Type A residual current and C tripping characteristic. It is rated 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1, a rated impulse withstand voltage of 4 kV, and a rated short-circuit capacity of 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. It mounts on DIN rail in any position, uses screw terminals with 2.8 N·m tightening torque, and operates from -25 to 55 °C.
- DS201 C6 APR300
The ABB DS201 C6 APR300 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 6 A with C tripping characteristic and 300 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity, 7.5 kA rated service short-circuit breaking capacity, and 10 kA rated conditional short-circuit current. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two modular spacings, screw terminals, DIN-rail mounting, and dimensions 35 mm by 85 mm by 69 mm.
- DS201 C8 A300
The ABB DS201 C8 A300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 8 A and 300 mA residual current, Type A. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Two-module DIN-rail device, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 K1 A30
The ABB DS201 K1 A30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 1 A, 30 mA Type A residual current, and K tripping characteristic. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and dielectric test voltage 2 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, two modular spacings, screw terminals, DIN-rail mounting, 2.8 N·m tightening torque, and dimensions 35 mm by 85 mm by 69 mm.
- DS201 K1 A300
ABB DS201 K1 A300 is a 1P+N residual current breaker with overcurrent protection (RCBO) for single-phase circuits. It provides a rated current of 1 A, rated residual current of 300 mA, Type A residual current, and K tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated frequency is 50 to 60 Hz. The device has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Screw terminals accept conductors from 0.75 to 25 mm², with 12 mm stripping length and 2.8 N·m tightening torque. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1.