Industrial Automation Parts. Prompt replies from real people.

ABB NS53E-20 24V 6A 8P Contactor Relay

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB NS53E-20?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB NS53E-20 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
NS53E-20
Material Number
1SBH101001R2053
Manufacturer
ABB
Product ID
69863

Get a Free Quote

Request pricing and availability for NS53E-20.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.26 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Auxiliary Contacts: 5 NO and 3 NC contacts
  2. Rated Operational Voltage: 690 V for both auxiliary and main circuits
  3. Rated Operational Current AC-15: 6 A at 24 / 127 V, 4 A at 220 / 240 V, 3 A at 400 / 440 V, 2 A at 500 V and 690 V
  4. Rated Operational Current DC-13: 6 A / 144 W at 24 V, 2.8 A / 134 W at 48 V, 1 A / 72 W at 72 V, 0.55 A / 60 W at 110 V, 0.55 A / 69 W at 125 V, 0.27 A / 60 W at 220 V, 0.27 A / 68 W at 250 V
  5. Thermal and Short-time Ratings: 10 A conventional free-air thermal current at 40 °C and 140 A short-time withstand current for 0.1 s or 100 A for 1 s
  6. Switching Frequency: 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13
  7. Standards: IEC 60947-5-1, EN 60947-5-1, UL 508 and CSA C22.2 No. 14
  8. Dimensions and Weight: 45 mm width, 100.2 mm depth, 68 mm height, 0.26 kg net weight
NS53E-20

Product Information

Technical Specifications

Specifications for NS53E-20

ParameterValue
Product Net Width45 mm
Product Net Depth / Length100.2 mm
Product Net Height68 mm
Product Net Weight0.26 kg
Number of Auxiliary Contacts NO5
Number of Auxiliary Contacts NC3
StandardsIEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (400440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 V 60 Hz 24 V
ParameterValue
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeScrew Terminals
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 16 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 13 g Shock Direction: A 20 g Shock Direction: B1 5 g Shock Direction: B2 15 g
Resistance to Vibrations3g Closed Position & 2g Open Position 5 ... 300 Hz
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4761 >> Magnet contactor, AC-switching
Manufacturer ID1SBH101001R2053

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp