Product Model
NS71ES-20
Material Number
1SBH101004R2071
Manufacturer
ABB
Product ID
70061

Get a Free Quote

Request pricing and availability for NS71ES-20.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.26 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Auxiliary Contacts: 7 NO and 1 NC contacts
  2. Coil and Circuit Ratings: 24 V control circuit at 50/60 Hz, 690 V rated operational voltage for auxiliary and main circuits, and 690 V rated insulation voltage per IEC 60947-5-1 and VDE 0110 (Gr. C), 600 V per UL/CSA
  3. Current Ratings: 10 A conventional free-air thermal current at 40 °C per IEC 60947-5-1, 140 A short-time withstand current for 0.1 s and 100 A for 1 s, AC-15 rated operational current from 6 A at 24/127 V to 2 A at 690 V, and DC-13 rated operational current from 6 A / 144 W at 24 V to 0.27 A / 68 W at 250 V
  4. Switching Frequency: 1200 cycles per hour maximum electrical for AC-15, 900 cycles per hour for DC-13, and 3600 cycles per hour maximum mechanical
  5. Terminals and Wire Capacity: Spring terminals with 0.75 to 2.5 mm² rigid or flexible-with-ferrule capacity and 10 mm stripping length for auxiliary and control circuits, IP20 protection on auxiliary and coil terminals
  6. Operating Conditions: -40 to 70 °C ambient air temperature near contactor in free air, 3000 m maximum operating altitude without derating, and climatic withstand Category B per IEC 60947-1 Annex Q
  7. Standards and Dimensions: IEC 60947-5-1, EN 60947-5-1, UL 508, and CSA C22.2 No. 14, 45 mm width, 110.7 mm depth, 68 mm height, 0.26 kg net weight
NS71ES-20

Product Information

Technical Specifications

Specifications for NS71ES-20

ParameterValue
Product Net Width45 mm
Product Net Depth / Length110.7 mm
Product Net Height68 mm
Product Net Weight0.26 kg
Number of Auxiliary Contacts NO7
Number of Auxiliary Contacts NC1
StandardsIEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (400440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
ParameterValue
Rated Control Circuit Voltage (Uc)50 Hz 24 V 60 Hz 24 V
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeSpring Terminals
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 16 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 13 g Shock Direction: A 20 g Shock Direction: B1 5 g Shock Direction: B2 15 g
Resistance to Vibrations3g Closed Position & 2g Open Position 5 ... 300 Hz
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4761 >> Magnet contactor, AC-switching
Manufacturer ID1SBH101004R2071

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.