- VB7-30-01-F-02
ABB invertible contactor VB7-30-01-F-02, manufacturer ID GJL1311903R0012. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Coil voltage is 42 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Rated insulation voltage is 690 V, with rated impulse withstand voltage 6 kV for the main circuit. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.345 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20.
- VB7-30-01-F-80
ABB VB7-30-01-F-80 invertible contactor with manufacturer ID GJL1311903R8010. Three-pole device with 3 NO main contacts and 1 NC auxiliary contact. Rated operational voltage: main and auxiliary circuits 690 V AC, 250 V DC. Rated control circuit voltage 220 to 240 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.345 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7-30-01-P-01
The ABB VB7-30-01-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated control circuit voltage of 24 V AC and coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, with a net weight of 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- VB7-30-01-P-02
The ABB VB7-30-01-P-02 is a three-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. Its control circuit is rated 42 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Main and auxiliary circuits are rated 690 V AC and 250 V DC; rated impulse withstand voltage for the main circuit is 6 kV, and rated insulation voltage is 690 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep; net weight is 0.345 kg. Main circuit terminals provide IP20 protection.
- VB7-30-01-P-80
The ABB VB7-30-01-P-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, weighs 0.345 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. The main circuit is rated 690 V AC, 6 kV impulse withstand, and 12 A AC-1 at 220/240 V and 380/440 V, 6 A at 690 V. AC-3 rated power is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three phase. The coil is 220 to 240 V AC. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB7-30-01-P-84
The ABB VB7-30-01-P-84 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V AC in the main circuit and 110 to 127 V AC at the coil, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. Rated operational power in AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep; net weight is 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail to IEC 60715.
- VB7-30-01-P-85
ABB invertible contactor VB7-30-01-P-85, manufacturer ID GJL1311909R8015. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage is 690 V AC or 250 V DC for both main and auxiliary circuits; rated frequency is 50 Hz or 60 Hz for the main circuit, with DC also listed. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated control circuit voltage is 380 to 415 V AC, with coil operating limits of 0.85 to 1.1 x Uc per IEC 60947-4-1 at ambient temperatures up to 55 °C. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg. Main circuit terminals are IP20.
- VB7-30-10-01
The ABB VB7-30-10-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The coil operates at 24 V AC. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.