- VB6-30-01-80
ABB invertible contactor VB6-30-01-80, manufacturer ID GJL1211901R8010. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 220 to 240 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at both temperatures for 690 V. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions 96.2 x 57.5 x 46.7 mm, net weight 0.355 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6-30-01-84
ABB invertible contactor VB6-30-01-84, manufacturer ID GJL1211901R8014. Three-pole main contact configuration with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 110 to 127 V AC. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for 40 °C and 55 °C. Dimensions 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Mechanical durability 10,000,000 cycles. Ambient operating temperature -20 to +55 °C.
- VB6-30-01-85
ABB VB6-30-01-85 invertible contactor with manufacturer ID GJL1211901R8015. Three main poles, normally open, plus one normally closed auxiliary contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated control circuit voltage is 380 to 415 V AC. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.355 kg. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm², with 9 mm stripping length and 0.8 to 1.1 N·m tightening torque. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-4-1 and IEC/EN 60947-5-1.
- VB6-30-01-F-01
ABB invertible contactor VB6-30-01-F-01, manufacturer ID GJL1211903R0011. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage is 24 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures for 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-30-01-F-80
The ABB VB6-30-01-F-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit voltage is 220 to 240 V AC. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C.
- VB6-30-01-P-01
ABB VB6-30-01-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 24 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C according to IEC 60947-4-1. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage 6 kV, and rated insulation voltage 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, and 2.2 kW at 230 V. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, with a net weight of 0.345 kg. DIN-rail mounting is supported per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-30-01-P-02
ABB invertible contactor VB6-30-01-P-02, manufacturer ID GJL1211909R0012. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V AC or 220 V DC; auxiliary circuit is 690 V AC or 250 V DC. Rated control circuit voltage is 42 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Rated impulse withstand voltage is 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg.
- VB6-30-01-P-80
ABB invertible contactor VB6-30-01-P-80, manufacturer ID GJL1211909R8010. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 220 to 240 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Dimensions 96.2 x 57.5 x 47.7 mm, net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.