- B7-30-01-03
ABB B7-30-01-03 mini contactor, manufacturer ID GJL1311001R0013. Three-pole device with 3 NO main contacts and 1 NC auxiliary contact. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 48 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Dimensions are 52.5 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.175 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1 and UL 60947-4-1.
- B7-30-01-37
The ABB B7-30-01-37 is a 3-pole mini contactor with 3 normally open main contacts and 1 normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 200 V AC; coil operating limits are 0.85 to 1.1 x Uc for AC supply at ambient temperatures up to 55 °C. Rated operational power is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm², with 9 mm stripping length and 0.8 to 1.1 N·m tightening torque. DIN-rail mounting per IEC 60715.
- B7-30-01-80
The ABB B7-30-01-80 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Main and auxiliary terminals are IP20, accept rigid conductors from 1 to 4 mm², and use screw terminals with 0.8 to 1.1 N·m tightening torque. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-01-85
ABB mini contactor B7-30-01-85, manufacturer ID GJL1311001R8015. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage 690 V, rated impulse withstand voltage 6 kV. Dimensions 52.5 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.175 kg. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm², with 9 mm stripping length and 0.8 to 1.1 N·m tightening torque. DIN-rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operating temperature -25 to +55 °C.
- B7-30-01-F-01
ABB mini contactor B7-30-01-F-01, manufacturer ID GJL1311003R0011. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 24 V AC; rated operational power AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V and 500 V three-phase. Rated operational voltage is 690 V AC for main and auxiliary circuits, with rated impulse withstand voltage 6 kV. Dimensions are 52.5 mm width, 57.5 mm height and 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715 on TH35-15 or TH35-7.5 rail. Terminal degree of protection IP20. Ambient operating temperature range -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-01-F-03
ABB B7-30-01-F-03 mini contactor, manufacturer ID GJL1311003R0013. Three-pole device with three NO main contacts and one NC auxiliary contact, flat pin connections. Dimensions: 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage 48 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V three-phase. Mounting on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- B7-30-01-F-80
ABB mini contactor B7-30-01-F-80, manufacturer ID GJL1311003R8010. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, with rated impulse withstand voltage of 6 kV for main and auxiliary circuits. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles.
- B7-30-01-F-85
ABB B7-30-01-F-85 mini contactor, manufacturer ID GJL1311003R8015. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions 52.5 x 57.5 x 46.7 mm, 0.17 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.