- B7-30-01-F-01
ABB mini contactor B7-30-01-F-01, manufacturer ID GJL1311003R0011. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 24 V AC; rated operational power AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V and 500 V three-phase. Rated operational voltage is 690 V AC for main and auxiliary circuits, with rated impulse withstand voltage 6 kV. Dimensions are 52.5 mm width, 57.5 mm height and 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715 on TH35-15 or TH35-7.5 rail. Terminal degree of protection IP20. Ambient operating temperature range -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-01-F-03
ABB B7-30-01-F-03 mini contactor, manufacturer ID GJL1311003R0013. Three-pole device with three NO main contacts and one NC auxiliary contact, flat pin connections. Dimensions: 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage 48 V AC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V three-phase. Mounting on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- B7-30-01-F-80
ABB mini contactor B7-30-01-F-80, manufacturer ID GJL1311003R8010. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, with rated impulse withstand voltage of 6 kV for main and auxiliary circuits. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles.
- B7-30-01-F-85
ABB B7-30-01-F-85 mini contactor, manufacturer ID GJL1311003R8015. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions 52.5 x 57.5 x 46.7 mm, 0.17 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-01-P-01
ABB mini contactor B7-30-01-P-01, manufacturer ID GJL1311009R0011. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact, fitted with soldering pins. Rated control circuit voltage is 24 V AC; coil operating limits are 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight 0.17 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-01-P-03
The ABB B7-30-01-P-03 is a 3-pole mini contactor with soldering pins and one auxiliary NC contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The main circuit is rated 690 V AC and 220 V DC; the auxiliary circuit is rated 690 V AC and 250 V DC. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for both circuits. The coil is rated 48 V AC at 50, 60, or 400 Hz, with operating limits of 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Operation is rated -25 to +55 °C.
- B7-30-01-P-80
ABB B7-30-01-P-80 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated control circuit voltage is 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V or 500 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V, at 40 °C and 55 °C. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-01-P-84
ABB B7-30-01-P-84 mini contactor with three normally open main poles and one normally closed auxiliary contact. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated control circuit voltage is 110 to 127 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight 0.17 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.