- VBC6A-30-01-P-2.4
The ABB VBC6A-30-01-P-2.4 is an invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The control circuit is rated 17 to 32 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC, 6 kV impulse withstand, and AC-3 power of 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VBC6A-30-10-01
The ABB VBC6A-30-10-01 is an invertible contactor with three main NO contacts, one auxiliary NO contact, and a 24 V DC control circuit coil. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. Rated operational voltage is 690 V AC for the main circuit and 690 V AC / 250 V DC for the auxiliary circuit, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three phase. Mechanical durability is 10,000,000 cycles. Ambient air temperature range is -20 to +55 degrees C in operation. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC6A-30-10-03
The ABB VBC6A-30-10-03 is an invertible contactor with three main NO contacts and one auxiliary NO contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Control circuit voltage is 60 V DC.
- VBC6A-30-10-04
The ABB VBC6A-30-10-04 is a compact 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. The control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage is 6 kV, and rated insulation voltage is 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.355 kg.
- VBC6A-30-10-05
The ABB VBC6A-30-10-05 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The control circuit is rated 220 to 240 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage is 6 kV, and rated operational power AC-3 is 4 kW at 400 V three-phase. Terminals are IP20 and accept rigid conductors from 1 to 4 mm². It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VBC6A-30-10-1.4-81
The ABB VBC6A-30-10-1.4-81 is an invertible contactor with three main contacts, all normally open, and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC; the auxiliary circuit is rated 690 V AC and 250 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three phase. The control circuit is 24 V DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VBC6A-30-10-16
ABB VBC6A-30-10-16 invertible contactor, manufacturer ID GJL1213911R1106. Three-pole main circuit with three NO main contacts and no NC main contacts, plus one NO auxiliary contact and no NC auxiliary contacts. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage 48 V DC, with coil operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for 40 °C and 55 °C. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three phase. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg.
- VBC6A-30-10-F-01
ABB VBC6A-30-10-F-01 invertible contactor, manufacturer ID GJL1213913R0101. Three-pole device with three main NO contacts and one auxiliary NO contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Conventional free-air thermal current (Ith) is 20 A. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.345 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.