- VBC6A-30-01-03
ABB invertible contactor VBC6A-30-01-03, manufacturer ID GJL1213911R0013. Three-pole device with 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NC. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage is 60 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three phase. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC6A-30-01-04
The ABB VBC6A-30-01-04 is an invertible contactor with three main normally open contacts and one auxiliary normally closed contact. Its control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage is 6 kV, and rated insulation voltage is 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220 to 440 V, and 6 A at 690 V. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.355 kg.
- VBC6A-30-01-05
The ABB VBC6A-30-01-05 is an invertible contactor with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Its control circuit is rated 220 to 240 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, 6 kV rated impulse withstand voltage, and 20 A conventional free-air thermal current. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.355 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VBC6A-30-01-16
ABB VBC6A-30-01-16 invertible contactor, manufacturer ID GJL1213911R1016. Three-pole device with three main contacts NO and one auxiliary contact NC. Rated control circuit voltage 48 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C (220/240 V and 380/440 V), and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg.
- VBC6A-30-01-2.4-51
ABB invertible contactor VBC6A-30-01-2.4-51, manufacturer ID GJL1213911R5011. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 17 to 32 V DC; main circuit rated operational voltage is 690 V AC and 220 V DC, with rated frequency 50 Hz, 60 Hz, and DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- VBC6A-30-01-F-01
ABB invertible contactor VBC6A-30-01-F-01, manufacturer ID GJL1213913R0011. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height and 46.7 mm depth; net weight 0.345 kg.
- VBC6A-30-01-P-01
The ABB VBC6A-30-01-P-01 is a 3-pole invertible contactor with three NO main contacts and one NC auxiliary contact. The control circuit is rated 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Rated operational power is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and conventional free-air thermal current 12 A. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, with a net weight of 0.345 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- VBC6A-30-01-P-2.4
The ABB VBC6A-30-01-P-2.4 is an invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The control circuit is rated 17 to 32 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC, 6 kV impulse withstand, and AC-3 power of 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.