- DDA204 AC-25/0.3
ABB DDA204 AC-25/0.3 leakage protector, Type AC, 4-pole, rated current 25 A, rated residual current 300 mA, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 3 W; electrical endurance 10000 cycles. Connecting capacity: rigid 16 to 16 mm², flexible 16 to 16 mm². Ambient operating temperature -25 to 55 °C; degree of protection IP2X. Dimensions 105 mm width, 93 mm height, 76 mm depth; net weight 173 g. Standards: IEC/EN 61009 Ann. G. Manufacturer ID 2CSB204001R3250.
- DDA204 AC-25/0.5
The ABB DDA204 AC-25/0.5 is a four-pole residual current device block for assembly with MCBs. It is a Type AC device, responding to sinusoidal alternating residual currents, with a rated residual current of 500 mA and rated current of 25 A. Rated voltage is 230/400 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency is 50 to 60 Hz, operating characteristic is instantaneous, and electrical endurance is 10000 cycles. Power loss is 3 W. Connecting capacity is rigid 16 to 16 mm² and flexible 16 to 16 mm². Ambient operating temperature is -25 to 55 °C, and degree of protection is IP2X. It conforms to IEC/EN 61009 Ann. G. Dimensions are 105 mm width, 93 mm height, 76 mm depth; net weight 173 g.
- DDA204 AC-25/1
The ABB DDA204 AC-25/1 is a Type AC residual current device block for assembly with S200 series MCBs. It is a four-pole unit with a rated current of 25 A and a rated residual current of 1000 mA, operating instantaneously. Rated voltage is 230/400 V at 50 to 60 Hz, with rated insulation voltage 500 V and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009 Ann. G. Electrical endurance is 10000 cycles, power loss 3 W, and connecting capacity is rigid 16 to 16 mm² and flexible 16 to 16 mm². Ambient operating temperature range is -25 to 55 °C, degree of protection IP2X, net dimensions 105 mm wide, 93 mm high, 76 mm deep, weight 173 g.
- DDA204 AC-40/0.03
ABB DDA204 AC-40/0.03 leakage protector, manufacturer ID 2CSB204001R1400. Type AC residual current device, 4-pole, rated current 40 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Conforms to IEC/EN 61009 Ann. G. Power loss 4.8 W; electrical endurance 10000 cycles. Connecting capacity rigid 16 to 16 mm² and flexible 16 to 16 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Net dimensions 105 mm width, 93 mm height, 76 mm depth; net weight 173 g.
- DDA204 AC-40/0.03 AP-R
The ABB DDA204 AC-40/0.03 AP-R is a four-pole residual current circuit breaker with a rated current of 40 A and a rated residual current of 30 mA. It operates at 230/400 V and 50 to 60 Hz, with a power loss of 4.8 W. Residual current type is Type AC, and the operating characteristic is instantaneous (APR high immunity). It is built to EN 61009 Ann. G. Vibration resistance is 20 cycles with load 0.8 In at 1g or 1mm, 50 to 150 to 5 Hz. Shock resistance per IEC 60068-2-27 is 25g, 2 shocks, 13 ms. Dimensions are 105 mm width, 93 mm height, and 76 mm depth; net weight is 0.290 kg.
- DDA204 AC-40/0.1
The ABB DDA204 AC-40/0.1 is a 4-pole residual current device block with a rated current of 40 A and a rated residual current of 100 mA. It is Type AC, responding to sinusoidal alternating residual currents, and operates instantaneously. Rated voltage is 230/400 V at 50 to 60 Hz, with rated insulation voltage 500 V and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009 Ann. G. Power loss is 4.8 W and electrical endurance is 10000 cycles. Connecting capacity is rigid 16 to 16 mm² and flexible 16 to 16 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 105 mm width, 93 mm height, and 76 mm depth, weighing 173 g.
- DDA204 AC-40/0.3
The ABB DDA204 AC-40/0.3 is a four-pole residual current device block for assembly with MCBs of the S200 series and S300P. It is a Type AC device, responding to sinusoidal alternating residual currents, with a rated residual current of 300 mA and a rated current of 40 A. Rated voltage is 230/400 V at 50 to 60 Hz; rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It is instantaneous in operating characteristic and complies with IEC/EN 61009 Ann. G. Electrical endurance is 10000 cycles, power loss 4.8 W, and connecting capacity is rigid or flexible 16 to 16 mm². Dimensions are 105 mm width, 93 mm height, and 76 mm depth, weighing 173 g.
- DDA204 AC-40/0.5
ABB DDA204 AC-40/0.5 is a four-pole residual current device module for Type AC residual currents, rated 40 A and 500 mA. It is specified to IEC/EN 61009 Ann. G, with rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Operating characteristic is instantaneous; electrical endurance is 10000 cycles and power loss is 4.8 W. Connections accept rigid or flexible conductors of 16 to 16 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and dimensions are 105 mm width, 93 mm height, 76 mm depth, 173 g net weight. Manufacturer ID 2CSB204001R4400.