- AF1250-30-00-68
The ABB AF1250-30-00-68 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a conventional free-air thermal current of 1050 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg.
- AF1250-30-00-69
The ABB AF1250-30-00-69 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V, with an AC-1 rating of 1260 A at 40 °C, 1040 A at 55 °C, and 875 A at 70 °C at both 1000 V and 690 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. The control circuit operates at 50 Hz from 48 to 130 V. Main circuit terminals are bars. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg.
- AF1250-30-00-70
The ABB AF1250-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its rated operational voltage for the main circuit is 1000 V, and the rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. Rated operational current AC-1 (Ie) is 1260 A at 40 °C, 1040 A at 55 °C, and 875 A at 70 °C, at both 690 V and 1000 V. The rated control circuit voltage is 100 to 250 V at 50 Hz. Main circuit terminals are bars. Net dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250-30-00-71
The ABB AF1250-30-00-71 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V in the main circuit and a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-1 (Ie) is 1260 A at 40 °C, 1040 A at 55 °C, and 875 A at 70 °C, at both 1000 V and 690 V. The rated control circuit voltage is 250 to 500 V at 50 Hz. Main circuit terminals are bars. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg.
- AF1250-30-11-68
The ABB AF1250-30-11-68 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated control circuit voltage of 24 to 60 V DC. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg. Main circuit terminals are bars.
- AF1250-30-11-69
The ABB AF1250-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Coil control voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 210 mm W x 242 mm D x 344 mm H; net weight 14.6 kg. Main terminals accept 50 mm² bars.
- AF1250-30-11-70
The ABB AF1250-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 50/60 Hz, with bars for main circuit terminals. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Rated control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250-30-11-70 CT19001
The ABB AF1250-30-11-70 CT19001 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1140 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1140 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-1 is 1260 A at 1000 V and 40 degrees C. Mechanical durability is 0.5 million operating cycles, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.