- AF1250-30-11-70
The ABB AF1250-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 50/60 Hz, with bars for main circuit terminals. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Rated control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250-30-11-70 CT19001
The ABB AF1250-30-11-70 CT19001 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1140 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1140 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-1 is 1260 A at 1000 V and 40 degrees C. Mechanical durability is 0.5 million operating cycles, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250-30-11-71
The ABB AF1250-30-11-71 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, or DC. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250-30-22-69
The ABB AF1250-30-22-69 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg. The manufacturer ID is 1SFL647001R6922.
- AF1250-30-22-70
The ABB AF1250-30-22-70 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1260 A at 40 °C, 1040 A at 55 °C, and 875 A at 70 °C, at both 690 V and 1000 V. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high, with a net weight of 14.6 kg. Manufacturer ID: 1SFL647001R7022.
- AF1250-30-22-70 CT19001
The ABB AF1250-30-22-70 CT19001 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It is rated 1140 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 1050 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 1260 A at 1000 V and 40 °C, 1040 A at 55 °C, and 875 A at 70 °C. Rated insulation voltage is 1140 V to IEC 60947-4-1 and VDE 0110, and 600 V to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 0.5 million operations, with maximum switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250B-30-22-68
The ABB AF1250B-30-22-68 is a 3-phase, non-reversing AC contactor identified by manufacturer ID 1SFL647063R6822. It has a 3NO contact configuration and a control voltage range of 22-60 V DC. The contact rating is 1260 A at 1000 V. Coil consumption is 12 V·A holding and 785 V·A pull-in at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature limits are -25 to 50 °C close to the contactor fitted with a thermal overload relay (0.85 to 1.1 Uc) and -40 to 70 °C without a thermal overload relay (0.85 to 1.1 Uc). Dimensions are 210 mm wide, 242 mm deep, and 344 mm high; net weight is 14.6 kg.
- AF1250B-30-22-69
The ABB AF1250B-30-22-69 is a 3-pole AC non-reversing contactor with a general purpose rating of 1260 A. It has a control voltage range of 48–130 V and includes two auxiliary contacts. The contactor measures 210 mm wide, 242 mm deep, and 344 mm high, and weighs 14.6 kg. Coil consumption is 12 V·A holding and 1020 V·A pull-in at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature limits are -25 to 50 °C with a thermal overload relay and -40 to 70 °C without, both at 0.85 to 1.1 Uc. It is classified under ETIM EC000066 as a power contactor for AC switching.