- DRT2-MD16
The OMRON DRT2-MD16 is a remote I/O unit with 8 DC NPN inputs and 8 DC NPN outputs, each with 8 points per common. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. Output voltage is 24 VDC. It uses screw terminals and supports DIN 35 mm-track mounting.
- DRT2-MD16-1
The OMRON DRT2-MD16-1 is a remote I/O terminal with eight DC PNP input points and eight DC PNP output points, each configured as one common of eight. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. Output voltage is 24 VDC. The unit uses screw terminals.
- DRT2-MD16S
The OMRON DRT2-MD16S is a remote I/O terminal with 8 DC NPN input points and 8 DC NPN output points, each configured as one common of 8. Inputs operate at 24 VDC with 6 mA input current and 1.5 ms on and off times. Outputs operate at 24 VDC, rated 500 mA per point and 4.0 A per common, with 0.5 ms output on time and 1.5 ms output off time. The terminal uses an e-CON connector and mounts on DIN rail. No manufacturer part number or order code is supplied in the authoritative data.
- DRT2-MD16S-1
The OMRON DRT2-MD16S-1 is a DeviceNet remote I/O terminal with eight DC PNP input points and eight DC PNP output points, each configured as one common of eight. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. Outputs operate at 24 VDC. The terminal uses an e-CON connector.
- DRT2-MD16TA
The OMRON DRT2-MD16TA is a remote I/O module with 8 DC NPN input points and 8 DC NPN output points, each with 8 points per common. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. Outputs operate at 24 VDC. The module uses screw terminals.
- DRT2-MD16TA-1
The OMRON DRT2-MD16TA-1 is a DeviceNet remote I/O module with screw terminals. It provides 8 DC PNP input points and 8 DC PNP output points, each with 8 points per common. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. Output voltage is 24 VDC.
- DRT2-MD32B
OMRON DRT2-MD32B remote I/O module with 16 DC NPN input points and 16 DC NPN output points, each on a single common. Inputs operate at 24 VDC, 6 mA, with 1.5 ms on and off times. Outputs operate at 24 VDC, 300 mA per point and 2.0 A per common, with 0.5 ms on time and 1.5 ms off time. Connection is via MIL connector, and mounting is circuit board. The module is supplied from the communications connector. Noise immunity is specified as IEC61000-4-4, 2 kV on the power line.
- DRT2-MD32B-1
The OMRON DRT2-MD32B-1 is a remote I/O terminal with 16 DC PNP input points and 16 DC PNP output points, each with 16 points per common. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. The terminal uses a MIL connector.