- DRT2-MD16TA
The OMRON DRT2-MD16TA is a remote I/O module with 8 DC NPN input points and 8 DC NPN output points, each with 8 points per common. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. Outputs operate at 24 VDC. The module uses screw terminals.
- DRT2-MD16TA-1
The OMRON DRT2-MD16TA-1 is a DeviceNet remote I/O module with screw terminals. It provides 8 DC PNP input points and 8 DC PNP output points, each with 8 points per common. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. Output voltage is 24 VDC.
- DRT2-MD32B
OMRON DRT2-MD32B remote I/O module with 16 DC NPN input points and 16 DC NPN output points, each on a single common. Inputs operate at 24 VDC, 6 mA, with 1.5 ms on and off times. Outputs operate at 24 VDC, 300 mA per point and 2.0 A per common, with 0.5 ms on time and 1.5 ms off time. Connection is via MIL connector, and mounting is circuit board. The module is supplied from the communications connector. Noise immunity is specified as IEC61000-4-4, 2 kV on the power line.
- DRT2-MD32B-1
The OMRON DRT2-MD32B-1 is a remote I/O terminal with 16 DC PNP input points and 16 DC PNP output points, each with 16 points per common. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. The terminal uses a MIL connector.
- DRT2-MD32BV
The OMRON DRT2-MD32BV is a remote I/O terminal with 16 DC NPN input points and 16 DC NPN output points, each with 16 points per common. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. It uses a MIL connector and supports parallel mounting.
- DRT2-MD32BV-1
OMRON DRT2-MD32BV-1 remote I/O terminal with 16 DC PNP input points and 16 DC PNP output points, mounted on a circuit board with a MIL connector. Inputs operate at 24 VDC, 6 mA, with 1.5 ms on and 1.5 ms off times; all 16 inputs share one common. Outputs operate at 24 VDC, 300 mA per point and 2.0 A per common, with 0.5 ms on and 1.5 ms off times; all 16 outputs share one common. Communications power is supplied from the communications connector at 11 to 25 VDC. The unit conforms to IEC61000-4-4 with 2 kV noise immunity on the power line, and withstands vibration of 10 to 60 Hz (0.7-mm double amplitude) and 60 to 150 Hz (50 m/s²), 80 minutes each in X, Y, and Z directions.
- DRT2-MD32ML
The OMRON DRT2-MD32ML is a remote I/O module with 16 DC NPN input points and 16 DC NPN output points, each with 16 points per common. Inputs operate at 24 VDC and 6 mA, with input on and off times of 1.5 ms. Outputs operate at 24 VDC, with 300 mA per point and 4.0 A per common; output on time is 0.5 ms and off time is 1.5 ms. The terminal type is a MIL connector, and mounting is DIN rail. The legacy text's PNP reference conflicts with the specified DC NPN input and output types and is omitted.
- DRT2-MD32ML-1
The OMRON DRT2-MD32ML-1 is a remote I/O terminal with 16 DC PNP input points and 16 DC PNP output points, each with 16 points per common. Input voltage is 24 VDC at 6 mA, with input on and off times of 1.5 ms. Output voltage is 24 VDC. The unit uses MIL connectors.