- VSC-E15-10A10LS
The CKD VSC-E15-10A10LS is a mechanical vacuum switch in an ejector system. It uses a diaphragm-micro switch mechanism. Dimensions include A 12 mm, D1 10 mm, R R3/8, L1 56.5 mm, L2 50.2 mm, L3 20.7 mm, and P1 17.5 mm.
- VSC-E15-10A10S
CKD VSC-E15-10A10S ejector system. Structured dimensions: A 12 mm, D 10 mm, R R3/8 mm, L1 39 mm, L2 32.7 mm, L3 20.7 mm, P 24 mm, B 105.9 mm, E 30.9 mm, C 20.7 mm, F 22 mm. Nozzle diameter 1.5 mm. Ultimate vacuum 92 kPa. Suction flow 42 l/min. Air consumption 70 l/min. Weight 89.5 g. Parameters listed as "-" (M, D1, D2, P1, P2, E1, E2, C1, C2, opposite side) are not specified. The legacy description's 15 mm nozzle diameter and 10A intake flow rate conflict with the structured nozzle diameter of 1.5 mm and are omitted. No operating pressure, supply voltage, standard, certification, or application is supplied.
- VSC-E15-10A8J
The CKD VSC-E15-10A8J is an ejector system with a compact body. Port dimensions are 12 mm (A), 8 mm (D1), 12 mm (D2), and R3/8. Overall dimensions include L1 38 mm, L2 31.7 mm, L3 20.7 mm, and P 22 mm. The M, D, and P1 dimensions are not specified.
- VSC-E15-10A8LJ
The CKD VSC-E15-10A8LJ is an ejector system with a 1.5mm nozzle diameter. It reaches an ultimate vacuum of 92kPa, with a suction flow of 42l/min and air consumption of 70l/min. The unit weighs 99g. Dimensional data include A 12mm, D1 8mm, D2 12mm, R R3/8mm, L1 52.7mm, L2 46.4mm, L3 20.7mm, P1 14.5mm, P2 22mm, E1 88.1mm, E2 23.3mm, C1 18.2mm, C2 23.3mm, opposite side 19mm, and F 22mm. The model is identified as VSC-E15-10A8LJ. No manufacturer part number or order code is supplied.
- VSC-E15-10A8LS
The CKD VSC-E15-10A8LS is an ejector system supplied in the 8LS configuration. Its dimensions include A 12 mm, D1 8 mm, R R3/8 mm, L1 52.7 mm, L2 46.4 mm, L3 20.7 mm, and P1 14.5 mm. The 8LS configuration permits flexible installation. This catalog entry lists only the stated dimensional data for the VSC-E15-10A8LS.
- VSC-E15-10A8S
The CKD VSC-E15-10A8S is an ejector system supplied as a vacuum switch. Its listed dimensions are A 12 mm, D 8 mm, R R3/8, L1 39 mm, L2 32.7 mm, L3 20.7 mm, and P 24 mm. The M, D1, D2, and P1 dimensions are not specified. The unit is intended for vacuum transfer, movement, and insertion tasks.
- VSC-E15-8A10J
CKD VSC-E15-8A10J ejector system. Dimensions: A 11 mm, D1 10 mm, D2 12 mm, R R1/4 mm, L1 38 mm, L2 32 mm, L3 21 mm, P 22 mm. The M, D, and P1 dimensions are not specified.
- VSC-E15-8A10LJ
CKD VSC-E15-8A10LJ ejector system. Dimensions: A 11 mm, D1 10 mm, D2 12 mm, R R1/4 mm, L1 56.5 mm, L2 50.5 mm, L3 21 mm, P1 17.5 mm. The unit is intended for vacuum generation at small flow rates.