- VSC-E15-8A10LJ
CKD VSC-E15-8A10LJ ejector system. Dimensions: A 11 mm, D1 10 mm, D2 12 mm, R R1/4 mm, L1 56.5 mm, L2 50.5 mm, L3 21 mm, P1 17.5 mm. The unit is intended for vacuum generation at small flow rates.
- VSC-E15-8A10LS
CKD VSC-E15-8A10LS ejector system with a 1.5 mm nozzle diameter. Specifications include 92 kPa ultimate vacuum, 42 l/min suction flow, and 70 l/min air consumption. Dimensions: A 11 mm, D1 10 mm, R R1/4, L1 56.5 mm, L2 50.5 mm, L3 21 mm, P1 17.5 mm, P2 24 mm, E1 100.8 mm, E2 25.8 mm, C 20.2 mm, opposite side 19 mm, F 22 mm. Weight 91.5 g. No M, D, D2, P, B, E, C1, or C2 dimensions are stated. The legacy text's 15 mm nozzle diameter conflicts with the authoritative 1.5 mm value and is omitted. No manufacturer part number or order code is supplied.
- VSC-E15-8A10S
CKD VSC-E15-8A10S vacuum switch for ejector systems. Dimensions: A 11 mm, D 10 mm, R R1/4 mm, L1 39 mm, L2 33 mm, L3 21 mm, P 24 mm. The switch provides adjustable vacuum level settings.
- VSC-E15-8A8J
CKD VSC-E15-8A8J ejector system. Supplied dimensions: A 11 mm, D1 8 mm, D2 12 mm, R R1/4, L1 38 mm, L2 32 mm, L3 21 mm, P 22 mm, B 94 mm, E 29.2 mm, C1 18.2 mm, C2 23.3 mm, F 22 mm. Nozzle diameter is 1.5 mm. Ultimate vacuum is 92 kPa; suction flow is 42 l/min; air consumption is 70 l/min. Weight is 99.5 g. Parameters M, D, P1, P2, E1, E2, C, and opposite side are listed without values. No operating voltage, frequency, temperature range, standard, certification, or accessory is stated in the supplied data.
- VSC-E15-8A8LJ
The CKD VSC-E15-8A8LJ is an ejector system with a 1.5 mm nozzle diameter, an ultimate vacuum of 92 kPa, a suction flow of 42 l/min, and air consumption of 70 l/min. Its weight is 98 g. Dimensional data include A 11 mm, D1 8 mm, D2 12 mm, R R1/4, L1 52.7 mm, L2 46.7 mm, L3 21 mm, P1 14.5 mm, P2 22 mm, E1 88.1 mm, E2 23.3 mm, C1 18.2 mm, C2 23.3 mm, opposite side 19 mm, and F 22 mm. The legacy text's 8A nozzle and 8A vacuum port conflict with the structured 1.5 mm nozzle diameter and are omitted.
- VSC-E15-8A8LS
CKD VSC-E15-8A8LS ejector system with 1.5 mm nozzle diameter. Specifications include ultimate vacuum 92 kPa, suction flow 42 l/min, and air consumption 70 l/min. Dimensions: A 11 mm, D1 8 mm, R R1/4, L1 52.7 mm, L2 46.7 mm, L3 21 mm, P1 14.5 mm, P2 24 mm, E1 98.3 mm, E2 23.3 mm, C 18.1 mm, opposite side 19 mm, F 22 mm. Weight 86.5 g. A mechanical vacuum switch with diaphragm-micro switch provides pressure detection within a set pressure range of -20 to -66 kPa. The square-shaped body uses compressed air to generate vacuum for workpiece transport.
- VSC-E15-8A8S
CKD VSC-E15-8A8S ejector system with concentrated exhaust and silencer attachment. Nozzle diameter 1.5 mm; ultimate vacuum 92 kPa; suction flow 42 l/min; air consumption 70 l/min. Port R is R1/4. Dimensions: A 11 mm, D 8 mm, L1 39 mm, L2 33 mm, L3 21 mm, P 24 mm, B 104.2 mm, E 29.2 mm, C 18.2 mm, F 22 mm. Weight 87.5 g. Unspecified dimension fields (M, D1, D2, P1, P2, E1, E2, C1, C2, opposite side) are not stated. The legacy description's performance and application claims are not supported by the supplied data and are omitted.
- VSC-E20-10A10J
The CKD VSC-E20-10A10J is a vacuum ejector in an ejector system configuration. Dimensional data include A 12 mm, D1 10 mm, D2 12 mm, R R3/8, L1 38 mm, L2 31.7 mm, L3 20.7 mm, and P 22 mm. It is intended for vacuum level control and workpiece handling within those stated dimensions.