- VSC-E12-6A8J
The CKD VSC-E12-6A8J is an ejector system with an 8 mm A dimension, 8 mm D1 and D2 dimensions, and an R1/8 port. Overall dimensions include L1 28 mm, L2 24 mm, L3 16 mm, and P 16 mm. It is intended for vacuum generation in pneumatic circuits.
- VSC-E12-6A8LJ
The CKD VSC-E12-6A8LJ is an ejector system with a 1.2mm nozzle diameter. It produces an ultimate vacuum of 92kPa, with a suction flow of 27l/min and air consumption of 47l/min. The unit weighs 38g. Dimensional data include A 8mm, D1 8mm, D2 8mm, R R1/8mm, L1 45.7mm, L2 41.7mm, L3 16mm, P1 14.5mm, P2 16mm, E1 60.5mm, E2 20.3mm, C1 18.2mm, C2 18.2mm, opposite side 14mm, and F 16mm. Parameters M, D, P, B, E, and C are listed as -mm. The model number is VSC-E12-6A8LJ. No flow-rate condition, operating pressure, or application data is supplied.
- VSC-E12-6A8LS
The CKD VSC-E12-6A8LS is an ejector system with a 1.2 mm nozzle diameter, 92 kPa ultimate vacuum, 27 l/min suction flow, and 47 l/min air consumption. It weighs 34 g. Port R is R1/8, and dimensions A and D1 are 8 mm. Overall dimensions include L1 45.7 mm, L2 41.7 mm, L3 16 mm, P1 14.5 mm, P2 16 mm, E1 58.3 mm, E2 20.3 mm, C 18.1 mm, F 16 mm, and opposite side 14 mm. The legacy text cites 0°C to 60°C and 0.15 to 0.7 MPa air service pressure, but these conditions are not confirmed by the structured parameters.
- VSC-E12-6A8S
The CKD VSC-E12-6A8S is an ejector system with a 1.2 mm nozzle diameter. It reaches an ultimate vacuum of 92 kPa, with a suction flow of 27 l/min and air consumption of 47 l/min. The body weighs 31.5 g. Port R is R1/8, and the overall length B is 65.2 mm. Other dimensions include A 8 mm, D 8 mm, L1 28 mm, L2 24 mm, L3 16 mm, P 16 mm, E 27.2 mm, C 17 mm, and F 16 mm. The unit is intended for vacuum generation in pneumatic circuits. No operating pressure range, supply voltage, standard, or certification is supplied.
- VSC-E15-10A10J
CKD VSC-E15-10A10J ejector system with a 1.5mm nozzle diameter. It reaches an ultimate vacuum of 92kPa, with a suction flow of 42l/min and air consumption of 70l/min. The unit weighs 101.5g. Dimensional data include A 12mm, D1 10mm, D2 12mm, R R3/8mm, L1 38mm, L2 31.7mm, L3 20.7mm, P 22mm, B 95.7mm, E 30.9mm, C1 20.7mm, C2 23.3mm, and F 22mm. The legacy description mentions a mechanical vacuum switch and applications such as product transfer and positioning, but these are not confirmed by the structured parameters and are therefore not stated here.
- VSC-E15-10A10LJ
CKD VSC-E15-10A10LJ ejector system with a 1.5 mm nozzle diameter. It reaches an ultimate vacuum of 92 kPa, with a suction flow of 42 l/min and air consumption of 70 l/min. The unit weighs 104 g. Port R is R3/8. Dimensional data include A 12 mm, D1 10 mm, D2 12 mm, L1 56.5 mm, L2 50.2 mm, L3 20.7 mm, P1 17.5 mm, P2 22 mm, E1 90.6 mm, E2 25.8 mm, C1 20.2 mm, C2 23.3 mm, opposite side 19 mm, and F 22 mm. Parameters M, D, P, B, E, and C are listed as - mm and are not specified.
- VSC-E15-10A10LS
The CKD VSC-E15-10A10LS is a mechanical vacuum switch in an ejector system. It uses a diaphragm-micro switch mechanism. Dimensions include A 12 mm, D1 10 mm, R R3/8, L1 56.5 mm, L2 50.2 mm, L3 20.7 mm, and P1 17.5 mm.
- VSC-E15-10A10S
CKD VSC-E15-10A10S ejector system. Structured dimensions: A 12 mm, D 10 mm, R R3/8 mm, L1 39 mm, L2 32.7 mm, L3 20.7 mm, P 24 mm, B 105.9 mm, E 30.9 mm, C 20.7 mm, F 22 mm. Nozzle diameter 1.5 mm. Ultimate vacuum 92 kPa. Suction flow 42 l/min. Air consumption 70 l/min. Weight 89.5 g. Parameters listed as "-" (M, D1, D2, P1, P2, E1, E2, C1, C2, opposite side) are not specified. The legacy description's 15 mm nozzle diameter and 10A intake flow rate conflict with the structured nozzle diameter of 1.5 mm and are omitted. No operating pressure, supply voltage, standard, certification, or application is supplied.