- 750-657
WAGO 750-657 is an IO-Link master module in the I/O system product group, with four IO-Link ports and 4 x (3-wire) sensor and actuator connections. Transmission modes are 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), and 230.4 kBaud (COM 3); data width is 44 bytes, configurable. System supply is 5 VDC via data contacts at 40 mA; field supply is 24 VDC (-15 +20 %) via power jumper contacts at 50 mA with no external load. Isolation is 500 V system/field. Wiring uses 16 x Push-in CAGE CLAMP for 0.08 to 1.5 mm² (28 to 16 AWG) solid and 0.25 to 1.5 mm² (22 to 16 AWG) fine-stranded conductors, strip length 8 to 9 mm, permissible cable length 20 m. Dimensions are 12 mm wide, 100 mm high, 69 mm deep, for DIN-35 rail mounting. Operating ambient temperature is 0 to +55 °C; protection type IP20.
- 750-658
The WAGO 750-658 is a CAN gateway module in the I/O system. It supports CAN 2.0A with 11-bit identifiers and CAN 2.0B extended with 29-bit identifiers, at transmission rates of 10, 20, 50, 125, 250, 500, and 800 kbit/s with auto-baudrate. Operating modes are sniffer, transparent, and mapped. The data width is configurable to 8, 12, 16, 20, 24, 32, 40, or 48 bytes, including control/status byte. System supply is 5 VDC via data contacts, drawing 50 mA; field supply is 24 VDC via power jumper contacts, drawing 12 mA with no external load. Isolation is 500 V system/supply. Connection is 7 x CAGE CLAMP for 0.08 to 2.5 mm2 (28 to 14 AWG) conductors, strip length 8 to 9 mm. Dimensions are 12 mm wide, 100 mm high, and 67.8 mm deep, mounted on DIN-35 rail. Operating ambient temperature is 0 to +55 degrees C; protection type IP20.
- 750-658/040-000
WAGO 750-658/040-000 is a CAN gateway module for DIN-35 rail mounting. It provides one CAN interface input and supports operating modes: sniffer mode, transparent mode, and mapped mode. Transmission rates are 10, 20, 50, 125, 250, 500, and 800 kbit/s (auto-baudrate), with data formats per 2.0 A standard (11-bit ID) and 2.0 B extended (29-bit ID). Data width is configurable to 8, 12, 16, 20, 24, 32, 40, or 48 bytes including control/status byte. System supply is 5 VDC via data contacts at 50 mA; field supply is 24 VDC (-25 +30%) via power jumper contacts, with derating required. Connection is 7 x CAGE CLAMP for 0.25 to 2.5 mm² (24 to 14 AWG), strip length 8 to 9 mm. Dimensions are 12 mm wide, 100 mm high, 67.8 mm deep. Operating temperature is -40 to +70 °C; protection type IP20.
- 750-660/000-001
WAGO 750-660/000-001 is an 8-channel fail-safe digital input module for PROFIsafe V1.3 networks. Inputs are voltage type, 24 VDC, clock sensitive, each with a fail-safe test pulse and typical input current of 2.2 mA at signal 1. Achievable safety classes are 8 x Cat. 2/SIL 2 or 4 x Cat. 4/SIL 3, referencing IEC 61508-1 -7 and EN 954-1 Cat. 4, with a 10-year proof test interval. The PROFIsafe address is adjustable via DIP switch or engineering software. Response times: ton(L->H) = 13 ms to 71 ms; toff(H->L) = 13 ms to 26 ms, plus 2 x local bus runtime, 2 x fieldbus runtime, and PLC runtime. Supply is 5 VDC system via data contacts, 40 mA, and 24 VDC (-15 +20 %) field via power jumper contacts. Connection is 16 x CAGE CLAMP; width 24 mm; DIN-35 rail mounting.
- 750-661/000-003
WAGO 750-661/000-003 is a fail-safe 4-channel digital input module for PROFIsafe V2 networks. It provides four clock-sensitive, fail-safe voltage inputs with test pulse, rated 24 VDC, with typical input current of 2.2 mA per channel at signal 1 and maximum signal frequency of 50 Hz. The PROFIsafe address is adjustable via DIP switch or engineering software. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-15 to +20 percent) via power jumper contacts; system supply is 5 VDC via data contacts, drawing 145 mA. Wiring uses 8 x CAGE CLAMP connections for 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 8 to 9 mm. Dimensions are 12 mm wide, 100 mm high, 67.8 mm deep, mounted on DIN-35 rail.
- 750-661/000-004
WAGO 750-661/000-004 is a fail-safe 4-channel digital input module with voltage signal type 24 VDC and 4 fail-safe inputs with test pulse. It supports PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET); the PROFIsafe address is adjustable via DIP switch or engineering software. Input characteristic is Type 1 per IEC 61131, with typical input current 3 mA per channel at signal 1 and maximum signal frequency 50 Hz. Achievable safety classes are SIL 3, Category 4, PLe two-channel, and SIL 2, Category 2, PLd one-channel, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-25 to +30%) via power jumper contacts; system supply is 5 VDC via data contacts, drawing 120 mA. Connection is 8 x CAGE CLAMP, DIN-35 rail mounting, 12 mm wide.
- 750-662/000-003
WAGO 750-662/000-003 is a fail-safe 8-channel digital input module for PROFIsafe V2 networks. It provides eight clock-sensitive, voltage-type inputs rated 24 VDC, each a fail-safe input with test pulse; typical input current per channel at signal 1 is 2.2 mA, and maximum signal frequency is 50 Hz. The PROFIsafe address is adjustable via DIP switch or engineering software. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. System supply is 5 VDC via data contacts, drawing 148 mA; field supply is 24 VDC SELV/PELV (-15 to +20 percent) via power jumper contacts rated 10 A. Wiring uses 16 CAGE CLAMP connections for 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 8 to 9 mm. Dimensions are 24 x 100 x 67.8 mm, DIN-35 rail mounting. End of sale was 2023-06-30.
- 750-662/000-004
WAGO 750-662/000-004 is a fail-safe 8-channel digital input module for PROFIsafe networks. It supports PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET), with the address adjustable via DIP switch or engineering software. Inputs are 24 VDC, Type 1 per IEC 61131, each drawing typically 3 mA, with a maximum signal frequency of 50 Hz. Sensor connection is 8 x fail-safe input with test pulse. Achievable safety classes are SIL 3, Category 4, PLe (two-channel) and SIL 2, Category 2, PLd (one-channel), per IEC 61508-1 -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-25 +30 %); system supply is 5 VDC via data contacts. Wiring uses 16 x CAGE CLAMP®; mounting is DIN-35 rail; width is 24 mm.