- 750-469/000-001
WAGO 750-469/000-001 is a 2-channel analog input module for thermocouple signals, with 2 x (2-wire) sensor connection and 8 x CAGE CLAMP connections for solid or fine-stranded conductors of 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 8 to 9 mm. Data width is 2 x 16-bit data plus optional 2 x 8-bit control/status. Resolution is 0.1 °C over the entire range; typical conversion time is 320 ms. Measurement error at 25 °C is less than ±6 K (voltage input less than ±2 K; cold junction compensation less than ±4 K), temperature coefficient less than ±0.2 K/K. Internal resistance is 1000 kΩ. Supply voltage is 5 VDC via data contacts, current consumption 65 mA. Isolation is 500 V system/field. Dimensions are 12 mm wide, 100 mm high, 69.8 mm deep, for DIN-35 rail mounting.
- 750-469/000-003
WAGO 750-469/000-003 is a 2-channel analog input module for thermocouples and low-voltage measurement. It provides 2 analog inputs with 2 x (2-wire) sensor connection, 2 x 16-bit data plus optional 2 x 8-bit control/status, and 0.1 °C resolution over the entire range. Input resistance is 1000 kΩ; typical conversion time is ≤320 ms. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), with temperature coefficient < ±0.2 K/K. Cold junction compensation is at each pair of terminal blocks. Supply is 5 VDC via data contacts, current consumption 65 mA, isolation 500 V system/field. Inputs/outputs use 8 x CAGE CLAMP® terminals for 0.08–2.5 mm² (28–14 AWG), strip length 8–9 mm. Dimensions are 12 mm wide, 100 mm high, 69.8 mm deep, DIN-35 rail mounting, IP20, 0 to +55 °C operating.
- 750-469/000-006
WAGO 750-469/000-006 is a 2-channel analog input module for thermocouple J sensors, with 2 x (2-wire) sensor connection. Resolution is 0.1 °C over the entire range, with a typical conversion time ≤320 ms. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), and temperature coefficient is < ±0.2 K/K. Cold junction compensation is provided at each pair of terminal blocks. The module uses 8 x CAGE CLAMP® connections for 0.08 … 2.5 mm² / 28 … 14 AWG conductors, with 8 … 9 mm / 0.31 … 0.35 inches strip length. It measures 12 mm wide, 100 mm high, and 69.8 mm deep, mounts on DIN-35 rail, and operates from 0 … +55 °C.
- 750-469/000-008
WAGO 750-469/000-008 is a 2-channel analog input module for thermocouple type E with diagnostics. Each channel uses 2-wire sensor connection with a data width of 2 x 16-bit data and optional 2 x 8-bit control/status. Resolution is 0.1 °C over the entire range, typical conversion time is ≤ 320 ms, and internal resistance is 1000 kΩ. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), with temperature coefficient < ±0.2 K/K. The temperature range is ?100 … +1000 °C. Cold junction compensation is provided at each pair of terminal blocks. System supply is 5 VDC via data contacts, current consumption is 65 mA, and isolation is 500 V system/field. Mounting is on a DIN-35 rail.
- 750-469/000-200
WAGO 750-469/000-200 is a 2-channel analog input module for Thermocouple K sensors, with 2 x (2-wire) sensor connection and 8 x CAGE CLAMP connections. Data width is 2 x 16-bit data plus optional 2 x 8-bit control/status. Resolution over the entire range is 0.1 °C; typical conversion time is ≤320 ms. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), temperature coefficient < ±0.2 K/K. The temperature range is -100 to +1370 °C, with cold junction compensation at each pair of terminal blocks. Internal resistance is 1000 kΩ. Supply voltage is 5 VDC via data contacts; current consumption is 65 mA. Isolation is 500 V system/field. The module measures 12 mm wide, 100 mm high, and 69.8 mm deep, mounts on DIN-35 rail, and operates from 0 to +55 °C.
- 750-469/003-000
WAGO 750-469/003-000 is a 2-channel analog input module for thermocouple signals, with configurable signal type. It provides 2 x 16-bit data and optional 2 x 8-bit control/status, 0.1 °C resolution over the entire range, and a typical conversion time of ≤320 ms. Sensor types include thermocouple K; configurable L, J, E, T, N, U, B, R, S, and mV. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), with temperature coefficient < ±0.2 K/K. Cold junction compensation is at each pair of terminal blocks. Inputs use 8 x CAGE CLAMP® connections for 0.08 … 2.5 mm2 (28 … 14 AWG), strip length 8 … 9 mm. Isolation is 500 V system/field. The module measures 12 mm wide, 100 mm high, and 69.8 mm deep, mounts on DIN-35 rail, and operates from 0 … +55 °C at IP20.
- 750-470
WAGO 750-470 analog input module with two single-ended analog input channels. Signal type is current, 0 to 20 mADC, with 12-bit resolution and a maximum input resistance of 160 ohms. Sensor connection supports 2 x (2-wire, 3-wire). Input filter frequency is 50 Hz. Input voltage is non-linear and overload protected: U = 1.2 V + 100 ohms x I meas. Data width is 2 x 16-bit data plus 2 x 8-bit control/status (optional). Noise rejection is -100 dB at sampling frequency and -40 dB above sampling frequency. Typical conversion time is 80 ms or less. Measurement error at reference temperature 25 degrees C, maximum deviation at upper-range value, is 0.1 percent or less.
- 750-470/005-000
WAGO 750-470/005-000 is a 2-channel analog input module for DIN rail mounting. It accepts single-ended 0–20 mADC current signals via 2-wire or 3-wire sensor connections. Resolution is 12 bits, with a maximum input resistance of 160 Ω and a typical conversion time of 80 ms. The input filter frequency is 60 Hz; noise rejection is -100 dB at the sampling frequency and -40 dB above it. Input voltage is non-linear and overload protected, described as U = 1.2 V + 100 Ω x I meas. Data width is 2 x 16-bit data plus optional 2 x 8-bit control/status. Measurement error at a reference temperature of 25°C is ≤±0.1% of the upper-range value.