Industrial Automation Parts. Prompt replies from real people.

WAGO 750-469/000-003 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 750-469/000-003?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-469/000-003 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-469/000-003
Material Number
—
Manufacturer
WAGO
Product ID
42775

Get a Free Quote

Request pricing and availability for 750-469/000-003.

More parts to source? Send your whole list in one enquiry

Key specifications

Supply voltage (system)
5 VDC; Via data contacts
Weight
52g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. 2-Channel Analog Input Module: Two low-voltage analog inputs with 2-wire sensor connection and 16-bit data width per channel
  2. Temperature Measurement: Resolution of 0.1 °C over the entire range with a typical conversion time of ≤320 ms and cold junction compensation at each terminal block pair
  3. Measurement Accuracy: Measurement error at 25 °C is < ±6 K for temperature input, < ±2 K for voltage input, and < ±4 K for cold junction compensation, with a temperature coefficient of < ±0.2 K/K
  4. Status Indication: Green LEDs for AI 1 and AI 2 function and red LEDs for AI 1 and AI 2 error
  5. Connection and Mounting: 8 x CAGE CLAMP® connections for 0.08 to 2.5 mm² (28 to 14 AWG) conductors with 8 to 9 mm strip length, DIN-35 rail mounting, 12 mm width, and 500 V system/field isolation
750-469/000-003

Product Information

Technical Specifications

Specifications for 750-469/000-003

ParameterValue
Number of analog inputs2
Number of Channels2
Signal typeLow voltages
Sensor connection2 x (2-wire)
Data width2 x 16-bit data; 2 x 8-bit control/status (optional)
Internal resistance1000kΩ
Resolution (over entire range)0.1 °C
Conversion time (typ. ≤ 320ms
Measurement error (25 °C)< ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K)
Temperature coefficient< ±0.2 K/K
Sensor types±120 mV
Cold junction compensationat each pair of terminal blocks
Supply voltage (system)5 VDC; Via data contacts
Current consumption (5 V system supply)65mA
Isolation500 V system/field
IndicatorsLED (A, C) green: Function AI 1, AI 2; LED (B, D) red: Error AI 1, AI 2
Connection technology: inputs / outputs8 x CAGE CLAMP®
Connection type 1Inputs/Outputs
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Width12 mm / 0.472 inches
Height100 mm / 3.937 inches
Depth69.8 mm / 2.748 inches
Depth from upper-edge of DIN-rail62.6 mm / 2.465 inches
Mounting typeDIN-35 rail
Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Fire load1MJ
Weight52g
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-40 … 85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 2000 m / 0 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95%
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-4, marine applications
ParameterValue
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity &#60; 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity &#60; 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-01
eCl@ss 9.027-24-26-01
ETIM 9.0EC001596
ETIM 8.0EC001596
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4045454393113
Customs tariff number8538901000
End of Sale2023-12-31
End of Production2024-03-31
End of Delivery2024-04-01
End of Service and Repair2026-04-01
CAS-No.1303-86-2
REACH Candidate List Substance4-Methyl-1,2-cyclohexanedicarboxylic anhydride
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)50fee08c-019f-4d61-b20a-fd00b77ba1de
SCIP notification number (Belgium)4607f4dd-15bc-48e8-86a1-4096e3b5bcc5
SCIP notification number (Bulgaria)f6b08914-d23c-4a90-9069-877c176be816
SCIP notification number (Czech Republic)0db9d391-c455-4a48-a21d-9d0962bb6bf1
SCIP notification number (Denmark)e4a2a4ef-839e-4dd3-9916-f7cf4bf4278a
SCIP notification number (Finland)fe51ea03-17b6-43e9-be38-c5280df1886b
SCIP notification number (France)281a6eb6-07c4-4c54-aee2-46324b53ac82
SCIP notification number (Germany)8a969715-e170-4f40-8a26-a0d2c5ce57be
SCIP notification number (Hungary)5d62ba1f-a22b-4421-a23d-087575f96203
SCIP notification number (Italy)da0ffe97-b9b4-4576-b091-02a2cd7563d4
SCIP notification number (Netherlands)c40b5f2e-67e7-4341-aaef-5038d1b1937f
SCIP notification number (Poland)f2b9638e-5fc5-4ccf-bc83-04ee370f6a93
SCIP notification number (Romania)ae39142b-c742-41b3-bdc3-3e0a2298f062
SCIP notification number (Sweden)0c5c3e21-b933-4564-bec8-d7667807bdd7

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp