Industrial Automation Parts. Prompt replies from real people.

WAGO 787-3861/400-000 WAGO

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 787-3861/400-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 787-3861/400-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
787-3861/400-000
Material Number
—
Manufacturer
WAGO
Product ID
45127

Get a Free Quote

Request pricing and availability for 787-3861/400-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Isolation voltage (connectors housing)
DC 1.5 kV
Protection class
III
Series operation
No
Weight
55.6g
Nominal input voltage [V]
DC 24 V
Nominal output current Io nom
1 x 4 A (fixed setting)
See all specifications

Product Highlights

  1. Channel Configuration: Single channel with one nominal DC 24 V output, 4 A fixed setting, and default switched-off state
  2. Protection Response: Trips on overload and short circuit on the secondary side with load-dependent trip time of 4 ms to 100 s
  3. Input and Output Range: DC 18 to 30 V input and DC 18 to 30 V output with voltage drop of 320 mV or less
  4. Signaling and Remote Control: One status LED (green/yellow/red) and one control input (15 to 30 VDC active high, 0 to 5 VDC active low, max 0.015 A)
  5. Isolation and Protection: DC 1.5 kV isolation voltage at connectors housing, protection class III, IP20 per EN 60529, no reverse voltage protection, and 33 V suppressor diode on primary
787-3861/400-000

Product Information

Technical Specifications

Specifications for 787-3861/400-000

ParameterValue
NoteThe device is designed for use in SELV circuits.
Isolation voltage (connectors housing)DC 1.5 kV
Protection classIII
Protection typeIP20; per EN 60529
Reverse voltage protectionNo
Transient suppression (primary)Suppressor diode (33 V)
Parallel operation of single channelsNot permitted
Series operationNo
MTBF1,168,394 h
Number of jumper slots8
Connection technologyPush-in CAGE CLAMP®
WAGO connectorWAGO 857 Series
Solid conductor0.08 … 2.5 mm2 / 26 14 AWG
Fine-stranded conductor0.34 2.5 m㎡/ 22 14 AWG
Strip length9 10 mm / 0.35 0.39 inches
Note (conductor cross-section)Depending on the output current, use the conductor cross-sections tested and approved by UL:26 14 AWG (0.5 A);20 14 AWG (4 A)
Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches
Mounting typeDIN-35 rail
Fire load0.631MJ
Weight55.6g
Ambient temperature (operation)-25 … +70 °C
Ambient temperature (storage)-40 … 85 °C
Relative humidity10 95 % (no condensation permissible)
DeratingNo derating
Operating altitude≤ 2000 m (a.s.l.)
ParameterValue
Conformity markingCE; UKCA
Standards/specificationsEN 61000-6-2
ETIM 9.0EC001440
ETIM 8.0EC001440
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typeBag
Country of originIN
Customs tariff number85363010900
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
Nominal input voltage [V]DC 24 V
Input voltage rangeDC 18 30 V
Number of Channels1
Nominal output voltage [V]1 x DC 24 V
Output voltage rangeDC 18 30 V (Ue voltage drop)
Voltage drop≤ 320 mV
Nominal output current Io nom1 x 4 A (fixed setting)
Default settingswitched off
Trip time4 ms 100 s (load-dependent)
Switch-on capacity>?50000?µF (see instruction manual)
Switch-on behaviorTime-delayed channel switching (load-dependent, min. 0 ms/max. 500 ms)
Signaling1 x Status LED (green/yellow/red)
Operation status indicatorGreen LED (channel OK)
Remote input1 x Control input (15 30 VDC (active high); 0 5 VDC (active low); max. 0.015 A)
Power loss Pl≤ 0.4 W (no load)
Efficiency (typ.)98 %
Internal fuseT 8 A
Overvoltage categoryII
Pollution degree2

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp