- 788-548
WAGO 788-548 is a DIN-35 rail mount general purpose relay with two changeover contacts (DPDT, 2 Form C) and an AC 115 V nominal input voltage, ±10 % input voltage range, and 7 mA nominal input current at UN. Contact material is AgNi, with an 8 A limiting continuous current and maximum switching voltage of AC 250 V. It provides reinforced insulation between coil and contacts, 5 kVrms dielectric strength (control/load circuit, AC, 1 min), 4 kV rated surge voltage, and IP20 protection. Connection uses Push-in CAGE CLAMP® for 0.34 to 2.5 mm² (22 to 14 AWG) conductors with 9 to 10 mm strip length. It measures 15 mm wide, 86 mm high, and 73 mm deep from the upper DIN-rail edge, weighs 46.5 g, and operates from -40 to +70 °C at UN. A red LED indicates status.
- 788-549
WAGO 788-549 relay module with manual operation and a red LED status indicator. It has two changeover contacts made of AgNi, a nominal input voltage of AC 230 V with a ±10 % input voltage range, and a nominal input current of 4 mA at UN. The limiting continuous current is 8 A, and the maximum switching voltage is AC 250 V. Rated voltage is 250 V with a 4 kV rated surge voltage, pollution degree 3, and IP20 protection. Connection is via Push-in CAGE CLAMP® for 0.34 to 2.5 mm² (22 to 14 AWG) conductors, 9 to 10 mm strip length. Dimensions are 15 mm wide, 86 mm high, and 73 mm deep from the DIN-35 rail upper edge. Operating ambient temperature is -40 to +70 °C; UL operation is -40 to +50 °C. Standards/specifications: EN 61010-2-201.
- 788-608
WAGO 788-608 relay module, gray, for DIN-35 rail mounting. Nominal input voltage is AC 230 V with an input voltage range of ±10 % and nominal input current of 5 mA at UN. It has one changeover contact with AgNi + Au contact material, a limiting continuous current of 16 A, and maximum switching voltage of AC 250 V. Switching power is AC 4000 VA resistive; DC per load limit curve. A red LED indicates status. Connection uses Push-in CAGE CLAMP® for solid and fine-stranded conductors from 0.34 to 2.5 mm² (22 to 14 AWG), strip length 9 to 10 mm. Dimensions are 15 mm wide, 86 mm high, 54 mm deep from the upper DIN-rail edge. Rated voltage 250 V, rated surge voltage 4 kV, pollution degree 3, protection type IP20. Standards/specifications: EN 61010-2-201.
- 788-616
WAGO 788-616 relay module with two changeover contacts, AC 230 V nominal input voltage (±10 %), 5 mA nominal input current at UN, and 8 A limiting continuous current. Contact material is AgNi + Au; maximum switching voltage is AC 250 V, maximum resistive switching power AC 2000 VA, with AC-15 3 A at AC 250 V and DC-13 2 A at DC 24 V. Connections use Push-in CAGE CLAMP® for solid and fine-stranded conductors from 0.34 to 2.5 mm² (22–14 AWG), strip length 9–10 mm. Dimensions are 15 mm wide, 86 mm high, 54 mm deep from the DIN-35 rail upper edge. Protection type IP20; operating ambient temperature -40 to +70 °C. Standards/specifications: EN 61010-2-201.
- 788-701
WAGO 788-701 solid-state relay module, gray, for DIN-35 rail mounting. Nominal input voltage is DC 24 V; input ranges are DC 0–2.5 V (low level) and DC 15–30 V (high level), with nominal input current 10 mA at UN. Output: nominal DC 24 V, range DC 0–30 V, limiting continuous current 5 A, voltage drop ≤ 0.3 VDC. Turn-on time ≤ 50 µs, turn-off time ≤ 600 µs, switching frequency ≤ 100 Hz. Circuit type is 2-wire connection with red LED status indicator. Dielectric strength control/load circuit is 2.5 kVrms AC for 1 min. Connection technology is Push-in CAGE CLAMP; solid and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG); strip length 9–10 mm. Dimensions: 15 mm wide, 86 mm high, 64 mm depth from upper DIN-rail edge. Pollution degree 2, protection type IP20. Operating ambient temperature at UN: -40 to +70 °C; UL: -40 to +40 °C. Standards/specifications: EN 61000-6-2.
- 788-720
WAGO 788-720 solid-state relay module for DIN-35 rail mounting. Nominal input is DC 24 V, with low-level input range DC 0–4 V and high-level range DC 18–30 V; nominal input current at UN is 7 mA. Output is AC 230 V nominal, output voltage range AC 24–240 V, limiting continuous current 1 A, voltage drop ≤ 1.1 VAC, turn-on and turn-off times ≤ 10 ms, switching frequency 50/60 Hz. Circuit type is 2-wire connection. Dielectric strength between control and load circuit is 3.75 kVrms (AC, 1 min). Connection uses Push-in CAGE CLAMP® for solid and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG), strip length 9–10 mm. Dimensions: 15 mm wide, 86 mm high, 54 mm depth from DIN-rail upper edge. Protection type IP20. Red LED status indicator.
- 788-721
WAGO 788-721 solid-state relay module, 2-wire connection, with AC/DC 24 V nominal input voltage. Input voltage ranges are AC/DC 0 to 2.5 V (low level) and AC/DC 15 to 30 V (high level); nominal input current at UN is 10 mA. Output: AC 230 V nominal, AC 12 to 275 V (50/60 Hz) range, 4 A limiting continuous current, voltage drop ≤ 1.1 VAC, turn-on and turn-off times ≤ 10 ms. Switching frequency 50/60 Hz. Red LED status indicator. Push-in CAGE CLAMP connection accepts 0.34 to 2.5 mm² (22 to 14 AWG), strip length 9 to 10 mm. DIN-35 rail mounting, gray, IP20, pollution degree 2, dielectric strength 4 kVrms (control/load, AC, 1 min). Dimensions 15 x 86 x 64 mm. Operating ambient -20 to +70 °C; UL -20 to +40 °C. Standard EN 61000-6-2. A separator plate such as 209-191 is required above 250 V between adjacent relay modules.
- 789-1341
WAGO 789-1341 relay module with one changeover contact (SPDT, 1 Form C) and AgNi contact material. Nominal input voltage is DC 24 V with an input voltage range of ±10 %; nominal input current at UN is 17 mA. Limiting continuous current is 12 A, maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 3000 VA. Typical pull-in, drop-out, and bounce times are 15 ms, 8 ms, and 6 ms. Manual operation and a red LED status indicator are provided. Connection uses CAGE CLAMP® for solid and fine-stranded conductors from 0.2 to 2.5 mm² (24 to 14 AWG), with 9 to 10 mm strip length. DIN-35 rail mounting, IP20, 17.5 mm wide. Ambient operating temperature at UN is -25 to +50 °C. Standards/specifications: EN 60664-1. Inductive loads must be dampened with an effective protection circuit.