- 789-1341
WAGO 789-1341 relay module with one changeover contact (SPDT, 1 Form C) and AgNi contact material. Nominal input voltage is DC 24 V with an input voltage range of ±10 %; nominal input current at UN is 17 mA. Limiting continuous current is 12 A, maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 3000 VA. Typical pull-in, drop-out, and bounce times are 15 ms, 8 ms, and 6 ms. Manual operation and a red LED status indicator are provided. Connection uses CAGE CLAMP® for solid and fine-stranded conductors from 0.2 to 2.5 mm² (24 to 14 AWG), with 9 to 10 mm strip length. DIN-35 rail mounting, IP20, 17.5 mm wide. Ambient operating temperature at UN is -25 to +50 °C. Standards/specifications: EN 60664-1. Inductive loads must be dampened with an effective protection circuit.
- 789-1544
WAGO 789-1544 relay module with one changeover contact and a nominal input voltage of AC 230 V (input range ±10 %). Nominal input current at UN is 4 mA. Limiting continuous current is 12 A; maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 3000 VA. Contact material is AgNi. Rated voltage is 250 V with a 4 kV rated surge voltage. Dielectric strength is 3.5 kVrms control/load and 1 kVrms open contact, both AC for 1 min. Connection is via CAGE CLAMP for 0.2 to 2.5 mm² (24 to 14 AWG), strip length 9 to 10 mm. Dimensions are 17.5 mm wide, 90 mm high, 55 mm deep from the DIN-rail upper edge. Operating ambient temperature is -25 to +50 °C. Standards/specifications: EN 60664-1. Inductive loads must be dampened with an effective protection circuit.
- 789-1549
WAGO 789-1549 relay module with AC 230 V nominal input voltage (input range ±10%) and 4 mA nominal input current at UN. It has two changeover contacts made of AgNi, a limiting continuous current of 8 A, and a maximum switching voltage of AC 250 V. Maximum resistive switching power is AC 2000 VA; DC depends on the load limit curve. Recommended minimum load is 12 V / 10 mA. Typical pull-in time is 15 ms, drop-out 8 ms, bounce 7 ms. Mechanical life is 5 x 10^7 switching operations. Status is shown by a red LED. Connection uses CAGE CLAMP; solid and fine-stranded conductors accept 0.2 to 2.5 mm² (24 to 14 AWG). Protection type is IP20. Standards/specifications: EN 60664-1.
- 789-304
WAGO 789-304 relay module for DIN-35 rail mounting, 17.5 mm wide, gray DIN-rail-mount enclosure. Nominal input voltage is DC 24 V with an input voltage range of -15 to +10 % and nominal input current of 19 mA at UN. It has one changeover contact with AgNi 90/10 contact material, a limiting continuous current of 12 A, and a maximum switching voltage of AC 250 V. Maximum resistive switching power is AC 3000 VA, with DC per the load limit curve. Rated voltage is 250 V and rated surge voltage is 4 kV. Connection is via CAGE CLAMP for 0.2 to 2.5 mm² (24 to 14 AWG) conductors, strip length 9 to 10 mm. Protection type is IP20. Operation at UN is rated -25 to +40 °C. Standards/specifications: EN 60664-1.
- 789-323
WAGO 789-323 relay module, gray DIN-35 rail-mount enclosure, 17.5 mm wide, 90 mm high, 55 mm deep from the upper DIN-rail edge, 54.2 g. Nominal input voltage is DC 24 V with an input voltage range of -15 to +20 percent and nominal input current of 19 mA at UN. One make contact, AgSnO2 contact material, limiting continuous current 16 A, maximum switching voltage AC 250 V, maximum resistive switching power AC 4000 VA, recommended minimum load 12 V / 10 mA. Pull-in time is typically 15 ms, drop-out time 5 ms. CAGE CLAMP connection accepts 0.2 to 2.5 mm² (24 to 14 AWG), strip length 9 to 10 mm. Rated voltage 300 V, overvoltage category III, pollution degree 2, IP20, EN 61010-2-201. Inductive loads must be dampened with an effective protection circuit.
- 789-324
WAGO 789-324 relay module, gray DIN-rail-mount enclosure for DIN-35 rail. Nominal input voltage UN is DC 24 V with an input voltage range of -10 to +20 % and nominal input current of 19 mA at UN. One make contact, AgSnO2 with W pre-make contact, limiting continuous current 16 A, maximum switching voltage AC 250 V, maximum resistive switching power AC 4000 VA. Typical pull-in 10 ms, drop-out 5 ms, bounce 4 ms. Rated voltage 300 V, overvoltage category III, pollution degree 2, dielectric strength control/load circuit 4 kVrms (AC, 1 min). CAGE CLAMP connection accepts 0.2 to 2.5 mm² (24 to 14 AWG), strip length 9 to 10 mm. Protection type IP20. Dimensions 17.5 mm wide, 90 mm high, 55 mm deep from upper DIN-rail edge. Operating ambient temperature -20 to +40 °C. Standard: EN 61010-2-201.
- 789-508
WAGO 789-508 relay module with one changeover contact. Nominal input voltage is AC 230 V with an input voltage range of -15 to +10 percent; nominal input current at UN is 5 mA. The limiting continuous current is 12 A, maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 3000 VA. Contact material is AgNi 90/10. Typical pull-in and drop-out times are 15 ms each, bounce time 3 ms, and mechanical life is 10 million switching operations. The module mounts on DIN-35 rail, is 17.5 mm wide, 90 mm high, and 55 mm deep from the upper DIN-rail edge, with IP20 protection and CAGE CLAMP connection. It is gray and weighs 49.2 g.
- 789-520
WAGO 789-520 relay module for DIN-35 rail mounting in an 17.5 mm wide DIN-rail-mount enclosure. Nominal input voltage is AC/DC 24 V with an input voltage range of -15 to +20 % and nominal input current of 32 mA at UN. It has one make contact with AgSnO2 contact material, a limiting continuous current of 16 A, maximum AC switching voltage of 250 V, and maximum resistive switching power of AC 4000 VA. Rated voltage is 250 V and rated surge voltage is 4 kV. Connection uses CAGE CLAMP® for solid and fine-stranded conductors from 0.2 to 2.5 mm² (24 to 14 AWG), strip length 9 to 10 mm. Protection type is IP20. Operation at UN is -25 to +40 °C. Standards/specifications: EN 60664-1. Inductive loads must be dampened with an effective protection circuit to protect relay coils and contacts.