- 288-304
WAGO 288-304 relay module for DIN-35 rail mounting, gray, 20.5 mm wide, 85 mm high, 48 mm deep from the upper DIN-rail edge, 45 g. Nominal input voltage UN is DC 24 V with an input voltage range of ±10 % and nominal input current at UN of 22 mA. It has one changeover contact (AgNi 90/10), limiting continuous current 6 A, maximum switching voltage AC 250 V, and maximum resistive switching power AC 1500 VA. Typical pull-in, drop-out, and bounce times are 9 ms, 3 ms, and 2 ms. Connection uses CAGE CLAMP® with WAGO 236 Series connectors, accepting 0.08 … 2.5 mm2 (28 … 12 AWG) solid and fine-stranded conductors, strip length 5 … 6 mm. Reinforced insulation between control and load side per EN 61010-2-201; dielectric strength 4 kVrms control/load and 1 kVrms open contact (AC, 1 min). Operating ambient temperature at UN: -25 … +40 °C.
- 288-312
WAGO 288-312 relay module, gray, for DIN-35 rail mounting. Nominal input voltage is DC 24 V with an input voltage range of ±10 % and nominal input current of 22 mA at UN. It has two changeover contacts with AgNi 0.15 contact material, a limiting continuous current of 6 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1500 VA. Rated voltage is 250 V with a rated surge voltage of 2.5 kV and pollution degree 2. Dimensions are 22.5 mm wide, 85 mm high, and 48 mm deep from the upper DIN-rail edge. Connection uses CAGE CLAMP® technology with WAGO 236 Series connectors, accepting 0.08 to 2.5 mm² (28 to 12 AWG) conductors with 5 to 6 mm strip length. Operating ambient temperature at UN is -25 to +40 °C. Standards/specifications: EN 60664-1.
- 288-320
WAGO 288-320 relay module for lamp loads, with DC 24 V nominal input voltage and ±10 % input voltage range. Nominal input current at UN is 22 mA. The relay has one make contact with AgSnO2 contact material, a limiting continuous current of 16 A, maximum resistive inrush current of 25 A for 4 s, maximum switching voltage of AC 400 V, and maximum resistive switching power of AC 4000 VA. Typical pull-in, drop-out, and bounce times are 8 ms, 2 ms, and 2 ms; mechanical life is 30 x 10⁶ switching operations. CAGE CLAMP connection accepts 0.08 to 2.5 mm2 (28 to 12 AWG) conductors with 5 to 6 mm strip length. Dimensions are 20.5 mm wide, 85 mm high, and 47 mm deep from the DIN-35 rail upper edge. Operating ambient temperature at UN is -25 to +40 °C. Standards/specifications: EN 61010-2-201.
- 288-364
WAGO relay module 288-364 for DIN-35 rail mounting. Nominal input voltage is DC 24 V with an input voltage range of ±10 % and nominal input current of 20 mA at UN. It has one make contact with AgNi 0.15 contact material and a limiting continuous current of 5 A. Maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 1250 VA. Typical pull-in, drop-out, and bounce times are 4 ms, 6 ms, and 2 ms. Control and load circuits are separated by reinforced insulation with 4 kVrms dielectric strength at AC for 1 min. Connection uses CAGE CLAMP technology for 0.08 to 2.5 mm2 conductors. Dimensions are 13 mm wide, 85 mm high, and 47 mm deep from the DIN-rail upper edge. Operating ambient temperature at UN is -25 to +40 °C.
- 288-418
WAGO 288-418 relay module for secondary circuits, DIN-35 rail mounting. Nominal input voltage is AC/DC 230 V with an input voltage range of -15 to +20 percent and nominal input current of 14 mA at UN. It provides four make contacts and four break contacts; contact material is AgSnO2, limiting continuous current is 6 A, maximum switching voltage is AC 250 V, and maximum resistive switching power is AC 1500 VA. Rated voltage is 250 V. Dielectric strength is 2.5 kVrms for control/load and load/load circuits and 1.3 kVrms for open contacts, per EN 61010-1. Connection uses CAGE CLAMP with WAGO 256 Series connectors, accepting 0.08 to 2.5 mm2 (28 to 12 AWG), strip length 5 to 6 mm. Dimensions are 63.5 mm wide, 85 mm high, 40 mm deep from the DIN-rail upper edge. Operating ambient temperature is -40 to +70 degrees C.
- 288-504
WAGO 288-504 relay module for DIN-35 rail mounting, gray, 20.5 mm wide, 85 mm high, 48 mm deep from the upper DIN-rail edge, 40.9 g. Nominal input voltage UN is AC/DC 24 V with ±10 % input voltage range and 22 mA nominal input current at UN. One changeover contact, AgNi 90/10 contact material, 6 A limiting continuous current, maximum switching voltage AC 250 V, maximum resistive switching power AC 1500 VA. Typical pull-in 9 ms, drop-out 3 ms, bounce 2 ms. Electrical life at 23 °C with resistive load is 100 x 10³ switching operations; mechanical life is 30 x 10⁶ switching operations. CAGE CLAMP connection accepts 0.08 … 2.5 mm2 / 28 12 AWG, strip length 5 6 mm. Rated voltage 300 V, rated surge voltage 2.5 kV, pollution degree 2. Operating ambient temperature -25 … +40 °C. EN 60664-1.
- 288-508
WAGO 288-508 relay module, category Relays Optocouplers. Nominal input voltage UN is AC 230 V with an input voltage range of ±10 % and nominal input current of 7 mA at UN. It has one changeover contact with AgNi 90/10 contact material, a limiting continuous current of 6 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1500 VA. Connection uses CAGE CLAMP® technology with WAGO 236 Series connectors, accepting solid and fine-stranded conductors of 0.08 … 2.5 mm2 / 28 12 AWG, strip length 5 6 mm / 0.2 0.24 inches. Dimensions are 20.5 mm wide, 85 mm high, 48 mm deep from the upper DIN-35 rail edge. Operating ambient temperature at UN is -25 … +40 °C. Standards/specifications: EN 60664-1.
- 288-512
WAGO 288-512 relay module for DIN-35 rail mounting. Nominal input voltage is 24 VAC/VDC with an input voltage range of ±10 % and nominal input current of 22 mA at UN. It has two changeover contacts made of AgNi 0.15, a limiting continuous current of 6 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1500 VA. Rated voltage is 250 V with a rated surge voltage of 2.5 kV and pollution degree 2. Connection uses CAGE CLAMP® technology with a WAGO 236 Series connector, accepting 0.08 to 2.5 mm2 (28 to 12 AWG) solid or fine-stranded conductors, strip length 5 to 6 mm. Dimensions are 22.5 mm wide, 85 mm high, and 48 mm deep from the DIN-rail upper edge. Operating ambient temperature at UN is -25 to +40 °C. Standards/specifications: EN 60664-1.