- 288-508
WAGO 288-508 relay module, category Relays Optocouplers. Nominal input voltage UN is AC 230 V with an input voltage range of ±10 % and nominal input current of 7 mA at UN. It has one changeover contact with AgNi 90/10 contact material, a limiting continuous current of 6 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1500 VA. Connection uses CAGE CLAMP® technology with WAGO 236 Series connectors, accepting solid and fine-stranded conductors of 0.08 … 2.5 mm2 / 28 12 AWG, strip length 5 6 mm / 0.2 0.24 inches. Dimensions are 20.5 mm wide, 85 mm high, 48 mm deep from the upper DIN-35 rail edge. Operating ambient temperature at UN is -25 … +40 °C. Standards/specifications: EN 60664-1.
- 288-512
WAGO 288-512 relay module for DIN-35 rail mounting. Nominal input voltage is 24 VAC/VDC with an input voltage range of ±10 % and nominal input current of 22 mA at UN. It has two changeover contacts made of AgNi 0.15, a limiting continuous current of 6 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1500 VA. Rated voltage is 250 V with a rated surge voltage of 2.5 kV and pollution degree 2. Connection uses CAGE CLAMP® technology with a WAGO 236 Series connector, accepting 0.08 to 2.5 mm2 (28 to 12 AWG) solid or fine-stranded conductors, strip length 5 to 6 mm. Dimensions are 22.5 mm wide, 85 mm high, and 48 mm deep from the DIN-rail upper edge. Operating ambient temperature at UN is -25 to +40 °C. Standards/specifications: EN 60664-1.
- 288-564
WAGO 288-564 relay module, gray, for DIN-35 rail mounting. Nominal input voltage is AC/DC 24 V with an input voltage range of ±10 % and nominal input current of 20 mA at UN. It has one make contact with AgNi 0.15 contact material, a limiting continuous current of 5 A, maximum switching voltage of AC 250 V, and maximum resistive switching power of AC 1250 VA. Typical pull-in, drop-out, and bounce times are 4 ms, 6 ms, and 2 ms. Dimensions are 13 mm wide, 85 mm high, and 47 mm deep from the upper DIN-rail edge. Connection uses CAGE CLAMP technology with WAGO 236 Series connectors, accepting 0.08 to 2.5 mm2 (28 to 12 AWG) conductors with a 5 to 6 mm strip length. Rated voltage is 300 V; dielectric strength between control and load circuit is 4 kVrms for 1 minute. Standards/specifications: EN 61010-2-201.
- 289-965
WAGO 289-965 interface module for DIN-35 rail mounting in a mounting carrier. It provides two shielded RJ-45 connectors (8-pole, system connection) plus double-row PCB terminal blocks: WAGO 236 Series CAGE CLAMP® units at positions 2 and 7 accept 0.08 to 2.5 mm² (28 to 12 AWG) with 5 to 6 mm strip length, and WAGO 745 Series CAGE CLAMP® units at positions 4 and 5 accept 0.2 to 6 mm² (24 to 10 AWG) with 11 to 12 mm strip length. Nominal current is 1.5 A; dielectric strength contact/contact is 0.5 kVrms AC for 1 min; mating cycles are 500. Dimensions are 58 mm wide, 85 mm high, 45 mm deep from the upper DIN-rail edge; weight 70 g. Operating ambient temperature is -20 to +85 °C. Fire load is 1.038 MJ.
- 289-966
WAGO 289-966 interface module in the Relays Optocouplers category, mounting carrier housing for DIN-35 rail. It provides two shielded RJ-45 pluggable connectors (8-pole) plus PCB terminal blocks: 8-pole CAGE CLAMP® clamping units 2, 7 (WAGO 236 Series) accept 0.08 to 2.5 mm2 / 28 to 12 AWG with 5 to 6 mm strip length, and 4-pole CAGE CLAMP® clamping units 4, 5 (WAGO 745 Series) accept 0.2 to 6 mm2 / 24 to 10 AWG with 11 to 12 mm strip length. Nominal current is 1.5 A; dielectric strength contact/contact is 0.5 kVrms AC for 1 min; mating cycles 500. Shield connection is included, with a 27 mm wide WAGO shield clamping saddle for cable diameter up to 24 mm. Dimensions: 69 mm wide, 85 mm high, 40 mm depth from upper-edge of DIN-rail. Operating ambient temperature -20 to +85 °C. Weight 106.9 g.
- 788-101
WAGO 788-101 relay socket for 15 mm x 25 mm basic relays, with one changeover contact. Rated voltage is 300 V, overvoltage category II, pollution degree 3. Dielectric strength is 3.6 kVrms (control/load circuit, AC, 1 min) and 1 kVrms (open contact, AC, 1 min); insulation between control and load circuit is reinforced (safe isolation), and between adjacent devices of the same type basic insulation. Connection uses Push-in CAGE CLAMP® for solid and fine-stranded conductors from 0.34 to 2.5 mm² (22 to 14 AWG), strip length 9 to 10 mm. Dimensions are 15 mm wide, 86 mm high, 64 mm deep from the DIN-35 rail upper edge. Protection type IP20. Operating ambient temperature is -40 to +70 °C at UN. Standard: EN 61010-2-201.
- 788-102
WAGO 788-102 relay socket for 15 mm basic relays, gray, with 2 changeover contacts. Rated voltage 300 V; overvoltage category II; pollution degree 3. Dielectric strength is 3.6 kVrms (control/load circuit, AC, 1 min) and 1 kVrms (open contact, AC, 1 min). Insulation: reinforced insulation (safe isolation) between control and load circuits; basic insulation between load circuits and between adjacent devices of the same type. Connection technology is Push-in CAGE CLAMP®; solid and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG); strip length 9–10 mm (0.35–0.39 inches). Dimensions: width 15 mm, height 86 mm, depth from upper DIN-rail edge 54 mm. Mounting is DIN-35 rail. Protection type IP20. Operating ambient temperature at UN is -40 to +70 °C. Standards/specifications: EN 61010-2-201. Weight 30.7 g.
- 788-103
WAGO 788-103 relay socket for 25 mm basic relays, with 2 changeover contacts and a limiting continuous current of 8 A. Rated voltage is 300 V; maximum switching voltage is AC 300 V. Connection uses Push-in CAGE CLAMP® for solid and fine-stranded conductors from 0.34 to 2.5 mm² (22 to 14 AWG), with a strip length of 9 to 10 mm. Dimensions are 15 mm wide, 86 mm high, and 64 mm deep from the upper edge of the DIN-35 rail. Protection type is IP20. Dielectric strength is 3.6 kVrms control/load and 1 kVrms open contact, both AC, 1 min. Operating ambient temperature at UN is -40 to +70 °C. Standards/specifications: EN 61010-2-201. Color gray; weight 31 g.