Industrial Automation Parts. Prompt replies from real people.

Schneider LC1F115G622L Electric

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the Schneider LC1F115G622L?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1F115G622L cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1F115G622L
Material Number
—
Manufacturer
Schneider
Product ID
33164

Get a Free Quote

Request pricing and availability for LC1F115G622L.

More parts to source? Send your whole list in one enquiry

Key specifications

Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage
120 V AC 60 Hz
[Ie] rated operational current
200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1115 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
Hold-in power consumption in VA
55 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
IP degree of protection
IP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
See all specifications

Product Highlights

  1. Motor control contactor: 3-pole LC1F device rated for AC-1, AC-3, and AC-4 utilisation categories
  2. Rated operational current: 200 A at 40 °C in AC-1 up to 440 V AC and 115 A at 55 °C in AC-3 up to 440 V AC
  3. Motor power ratings: 55 kW at 380...400 V AC, 59 kW at 415/440 V AC, 75 kW at 500 V AC, 80 kW at 660...690 V AC, and 18.5 kW at 400 V AC in AC-4
  4. Control circuit: 120 V AC 60 Hz coil with 660 VA inrush and 55 VA hold-in power consumption
  5. Operating times: 23...35 ms closing and 5...15 ms opening
  6. Power circuit connections: 2 bars 20 x 3 mm, lugs-ring terminals, or bolted connection with 10 N.m tightening torque
  7. Auxiliary contacts: 2 NO + 2 NC
  8. Mechanical durability: 10 million cycles with maximum operating rate of 2400 cycles per hour at 55 °C
  9. Rated insulation voltage: 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C, with 8 kV impulse withstand voltage
  10. Ambient air temperature for operation: -40...60 °C
LC1F115G622L

Product Information

Technical Specifications

Specifications for LC1F115G622L

ParameterValue
Range of ProductTeSys F
Product or Component TypeContactor
Device short nameLC1F
Contactor applicationMotor controlResistive load
Utilisation categoryAC-1AC-4AC-3
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage120 V AC 60 Hz
[Ie] rated operational current200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1115 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current200 A (at 104 °F (40 °C))
Rated breaking capacity920 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1100 A 104 °F (40 °C) - 10 s640 A 104 °F (40 °C) - 30 s520 A 104 °F (40 °C) - 1 min400 A 104 °F (40 °C) - 3 min320 A 104 °F (40 °C) - 10 min
Associated fuse rating125 A aM at <= 440 V200 A gG at <= 440 V
Average impedance0.37 mOhm - Ith 200 A 50 Hz
[Ui] rated insulation voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole15 W AC-15 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Auxiliary contact composition2 NO + 2 NC
Motor power kW55 kW at 380...400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3)59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660...690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3)30 kW at 220...230 V AC 50/60 Hz (AC-3)18.5 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA)30 hp at 200 V AC40 hp at 230 V AC75 hp at 460 V AC100 hp at 575 V AC
Control circuit voltage limitsOperational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C))
Mechanical durability10 Mcycles
ParameterValue
Inrush power in VA660 VA, 60 Hz 0.3 68 °F (20 °C))
Maximum operating rate2400 cyc/h 131 °F (55 °C)
Operating time23...35 ms closing5...15 ms opening
Connections - terminalsPower circuit 2 bars 20 x 3 mmPower circuit lugs-ring terminals 1 0.1 in² (95 mm²)Power circuit connector 1 0.1 in² (95 mm²)Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable endPower circuit bolted connection
Tightening torquePower circuit 88.5 lbf.in (10 N.m)Control circuit 10.6 lbf.in (1.2 N.m)
Mounting SupportPlate
Heat dissipation12...16 W
StandardsIEC 60947-1JIS C8201-4-1EN 60947-1EN 60947-4-1IEC 60947-4-1
Product CertificationsBVRINACBDNVABSLROS (Lloyds register of shipping)ULCCCRMRoS
Hold-in power consumption in VA55 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
IP degree of protectionIP2X front face with shrouds IEC 60529IP2X front face with shrouds VDE 0106
Protective treatmentTH
Ambient Air Temperature for Operation-40...140 °F (-40...60 °C)
Ambient Air Temperature for Storage-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device140...158 °F (60...70 °C) at Uc
Mechanical robustnessVibrations contactor open2 Gn, 5...300 HzVibrations contactor closed6 Gn, 5...300 HzShocks contactor open9 Gn for 11 msShocks contactor closed15 Gn for 11 ms
Height10.4 in (265 mm)
Width6.4 in (163.3 mm)
Depth6.7 in (171 mm)
Operating altitude9842.52 ft (3000 m) without derating

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp