Q1Can you supply the Schneider LC1D115T7?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1D115T7 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1D115T7
Material Number
—
Manufacturer
Schneider
Product ID
31332

Get a Free Quote

Request pricing and availability for LC1D115T7.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit / 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit / 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
480 V AC 50/60 Hz
IP degree of protection
IP20 front face conforming to IEC 60529
See all specifications

Product Highlights

  1. Product Type: TeSys Deca contactor, device short name LC1D, 3-pole with 3 NO power poles
  2. Contactor Application: Resistive load and motor control
  3. Utilisation Category: AC-1, AC-3, AC-3e, and AC-4
  4. Rated Operational Voltage: Power circuit up to 1000 V AC at 25...400 Hz and up to 300 V DC
  5. Rated Operational Current: 200 A AC-1, 115 A AC-3, and 115 A AC-3e at up to 440 V AC and up to 140 °F (60 °C)
  6. Motor Power Ratings: AC-3 30 kW at 220...230 V AC, 55 kW at 380...400 V AC, 59 kW at 415...440 V AC, 75 kW at 500 V AC, 80 kW at 660...690 V AC, and 65 kW at 1000 V AC, all at 50/60 Hz
  7. Motor Power Ratings: AC-4 18.5 kW at 400 V AC at 50/60 Hz
  8. Control Circuit: 480 V AC at 50/60 Hz with built-in bidirectional peak limiting diode suppressor
  9. Auxiliary Contacts: 1 NO + 1 NC, mechanically linked and mirror contact
  10. Mounting: DIN rail or panel
LC1D115T7

Product Information

Technical Specifications

Specifications for LC1D115T7
ParameterValue
Product or component typeContactor
Range of productTeSys Deca Advanced
[Ue] rated operational voltagePower circuit: <= 1000 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage480 V AC 50/60 Hz
Control circuit voltage limits0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz1...1.15 Uc (55…70 °C):operational AC 50/60 Hz
Motor power kW30 kW at 220/230 V AC 50/60 Hz (AC-3)55 kW at 380/400 V AC 50/60 Hz (AC-3)59 kW at 415/440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660/690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3)30 kW at 220/230 V AC 50/60 Hz (AC-3e)55 kW at 380/400 V AC 50/60 Hz (AC-3e)59 kW at 415/440 V AC 50/60 Hz (AC-3e)75 kW at 500 V AC 50/60 Hz (AC-3e)80 kW at 660/690 V AC 50/60 Hz (AC-3e)65 kW at 1000 V AC 50/60 Hz (AC-3e)18.5 kW at 400 V AC 50/60 Hz (AC-4)
RangeTeSys
Connections - terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable endPower circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable endPower circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable endPower circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable endPower circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable endPower circuit: connector 1 10…120 mm² - cable stiffness: solid without cable endPower circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end
Height158 mm
Width120 mm
Depth136 mm
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C / 60…70 °C with derating
Product certificationsULCSACCCUKCACEEACMarine

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.