- CA45V
ABB CA45V compact distribution board, manufacturer ID 2CPX052195R9999. Surface-mounting steel enclosure with powder-coated traffic white (RAL 9016) finish, closed double door, and turn-handle closure. Rated operational voltage 400 V maximum; rated current 125 A. Five rows provide 240 DIN place units. Supplied assembled with distribution module and quick terminals. Power loss: 84.3 W at Δt = 20 K, 111.3 W at Δt = 25 K, 131.4 W at Δt = 30 K. Degree of protection IP44. Standards: DIN EN 61439-3.
- CA46K
ABB CA46K compact distribution board, manufacturer ID 2CPX052299R9999. Rated operational voltage 400 V maximum; rated current 125 A. Complies with DIN EN 61439-3. Steel housing, powder-coated traffic white (RAL 9016), surface mounting, closed door with double-leaf cover plate and turn-handle closure. Six rows, 192 DIN place units. Configuration: assembled with distribution module plus terminals; terminal type: no terminals. Power loss: 99.6 W at Δt = 20 K, 131.5 W at Δt = 25 K, 155.2 W at Δt = 30 K. Degree of protection IP44.
- CA4X-01
ABB CA4X-01 auxiliary contact block, manufacturer ID 1SBN011310R1001. It provides one normally closed (NC) auxiliary contact and no normally open (NO) contacts. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high, with a net weight of 0.014 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 500 V and 690 V, 6 A at 24/127 V, 4 A at 220/240 V, and 2.4 A at 400/440 V. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Standards: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5.
- CA4X-02
ABB CA4X-02 auxiliary contact block, manufacturer ID 1SBN011310R1002. It provides 2 NC auxiliary contacts and 0 NO auxiliary contacts, front mounting, with screw terminals. Dimensions are 43 mm width, 19.9 mm depth, and 23.6 mm height; net weight 0.024 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Standards: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5.
- CA4X-10
ABB auxiliary contact block, model CA4X-10, manufacturer ID 1SBN011310R1010. It provides 1 normally open (NO) auxiliary contact and 0 normally closed (NC) contacts. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high, with a net weight of 0.014 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V. Maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Standards: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5. Auxiliary terminals are IP20.
- CA4X-11
ABB auxiliary contact block, display model CA4X-11, manufacturer ID 1SBN011310R1011. It provides one normally open and one normally closed auxiliary contact, side mounting, with auxiliary circuit rated operational voltage 690 V at 50/60 Hz. Conventional free-air thermal current is 10 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V to IEC 60947-5-1 and VDE 0110 (Gr. C), 600 V to UL/CSA; rated impulse withstand voltage is 6 kV. Auxiliary terminals are IP20 to IEC 60529. Dimensions: 43 mm width, 19.9 mm depth, 23.6 mm height; net weight 0.024 kg.
- CA4X-20
ABB auxiliary contact block, model CA4X-20, manufacturer ID 1SBN011310R1020. It provides two normally open (NO) auxiliary contacts and no normally closed (NC) contacts. Dimensions are 43 mm width, 19.9 mm depth, 23.6 mm height, and 0.024 kg net weight. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 10 A according to IEC 60947-5-1 at 40 °C ambient. Rated operational current is 6 A at 24/127 V, 4 A at 220/240 V, 2.4 A at 400/440 V, and 2 A at 500 V and 690 V under AC-15. Standards listed: UL 60947-5-1, IEC/EN 60947-1, IEC/EN 60947-5-1, GB14048.5. Auxiliary terminals are IP20.
- CA5-01
ABB CA5-01 auxiliary contact block, manufacturer ID 1SBN010010R1001. It is a front-mounted, 1-pole auxiliary contact block with screw terminals, one normally closed (NC) instantaneous contact, and no normally open (NO) contacts. Dimensions are 11 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.014 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with AC-15 ratings of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Mechanical durability is 10 million cycles. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.