- B6-40-00-01
ABB B6-40-00-01 mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. Rated operational voltage is 690 V AC for the main circuit and 220 V DC for the main circuit. Rated control circuit voltage is 24 V AC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.175 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-40-00-02
The ABB B6-40-00-02 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 includes 4 kW at 400 V and 500 V three-phase. The control circuit voltage is 42 V AC. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-40-00-03
The ABB B6-40-00-03 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. The control circuit voltage is 48 V AC. Coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 times Uc at up to 55 °C. Terminals are IP20.
- B6-40-00-14
ABB B6-40-00-14 mini contactor, 4-pole with four NO main contacts and no NC main or auxiliary contacts. Rated operational voltage: main circuit 690 V AC, main circuit 220 V DC. Rated insulation voltage 690 V, rated impulse withstand voltage 6 kV. Rated operational current AC-1: 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at 55 °C, and 6 A at 690 V. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Coil voltage 12 V AC. Dimensions 52.5 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.175 kg. Mechanical durability 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- B6-40-00-80
The ABB B6-40-00-80 is a 4-pole mini contactor with four normally open main contacts and no auxiliary or normally closed contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit coil is rated 220 to 240 V AC, with operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 degrees C. Rated operational current AC-1 is 20 A at 40 degrees C and 16 A at 55 degrees C for 220 to 440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase.
- B6-40-00-84
The ABB B6-40-00-84 is a 4-pole mini AC contactor with four normally open main contacts and no auxiliary contacts. Its control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC or 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg.
- B6-40-00-85
The ABB B6-40-00-85 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. Its control circuit is rated 380 to 415 V AC, and the main circuit is rated 690 V AC or 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-40-00-F-01
ABB mini contactor B6-40-00-F-01, manufacturer ID GJL1211203R0001. Four-pole AC contactor with four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. Rated operational voltage: main circuit 690 V AC and 220 V DC. Rated control circuit voltage 24 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, 3 kW at 690 V three-phase. Dimensions 52.5 x 57.5 x 46.7 mm, 0.17 kg. Screw terminals, IP20. DIN-rail mounting per IEC 60715.