- B6-40-00-80
The ABB B6-40-00-80 is a 4-pole mini contactor with four normally open main contacts and no auxiliary or normally closed contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit coil is rated 220 to 240 V AC, with operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 degrees C. Rated operational current AC-1 is 20 A at 40 degrees C and 16 A at 55 degrees C for 220 to 440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase.
- B6-40-00-84
The ABB B6-40-00-84 is a 4-pole mini AC contactor with four normally open main contacts and no auxiliary contacts. Its control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC or 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg.
- B6-40-00-85
The ABB B6-40-00-85 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. Its control circuit is rated 380 to 415 V AC, and the main circuit is rated 690 V AC or 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-40-00-F-01
ABB mini contactor B6-40-00-F-01, manufacturer ID GJL1211203R0001. Four-pole AC contactor with four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. Rated operational voltage: main circuit 690 V AC and 220 V DC. Rated control circuit voltage 24 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, 3 kW at 690 V three-phase. Dimensions 52.5 x 57.5 x 46.7 mm, 0.17 kg. Screw terminals, IP20. DIN-rail mounting per IEC 60715.
- B6-40-00-F-80
The ABB B6-40-00-F-80 is a four-pole mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit operates at 220 to 240 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-40-00-F-84
The ABB B6-40-00-F-84 is a 4-pole mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, a rated impulse withstand voltage of 6 kV, and a conventional free-air thermal current of 20 A. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-40-00-F-85
The ABB B6-40-00-F-85 is a mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit voltage is 380 to 415 V AC at 50 Hz, 60 Hz, or 400 Hz. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220 to 440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B6-40-00-P-03
ABB B6-40-00-P-03 mini contactor, 4-pole with four normally open main contacts and no auxiliary contacts. Rated operational voltage is 690 V AC for the main circuit and 220 V DC; rated insulation voltage is 690 V, with UL/CSA rating 600 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V three phase, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Control circuit voltage is 48 V AC. Dimensions: 47.5 mm width, 45.2 mm height, 47.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.