- 140G-H3F3-D16-AJ
The Rockwell 140G-H3F3-D16-AJ is a three-pole motor protection circuit breaker with a rated permanent current Iu of 160 A and a toggle control element. It uses a T/M-adjustable thermal/adjustable magnetic (TMA) trip unit, with thermal trip current Ir adjustable from 112 to 160 A and magnetic trip current Im from 800 to 1600 A. The device is a complete unit with protection unit and one auxiliary change-over contact. Rated impulse withstand voltage Uimp is 8 kV, insulation voltage Ui is rated 1000 V per IEC, and interrupting rating is 35 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 rated ultimate short-circuit breaking capacity Icu is 85 kA at 220 to 230 V AC, 50/60 Hz. Main circuit connection is front-side screw connection. Degree of protection is IP40. Dimensions are 90 mm width, 130 mm height, and 82.5 mm depth. Weight is 1.742 kg.
- 140G-H3H4-C25
The Rockwell 140G-H3H4-C25 is a motor protection circuit breaker with an H-frame molded case and an LSI adjustment type. Its trip unit rating is 25A. The IEC breaking capacity is 50kA at 415V. It is certified to UL489, CSA22.2 No. 5, and IEC 60947-2, and holds UL Listed, CSA Certified, CE, and CCC certifications. Dimensions are 20.8 cm height, 13.0 cm width, and 14.5 cm length; weight is 1.497 kg. The unit is not repairable. Stock status is non-stocked, preferred availability is false, and quick turnaround is false. Lead time is 48.
- 140G-H3H4-D12
The Rockwell 140G-H3H4-D12 is a four-pole motor protection circuit breaker with a rated permanent current of 125 A and a toggle control element. It is a complete device with an electronic LSI trip unit providing long-time, short-time, and high instantaneous protection. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 1000 V per IEC. Interrupting rating is 35 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 rated ultimate short-circuit breaking capacity is 85 kA at 220 to 230 V AC, 50/60 Hz. Electrical life is 8000 cycles at 415 V AC. No integrated under voltage release or earth fault protection is included.
- 140G-H3H4-D16
The Rockwell 140G-H3H4-D16 is a four-pole motor protection circuit breaker with electronic LSI protection and a 160 A trip unit rating. It is not repairable. Dimensions are 22.225 mm height, 13.589 mm width, and 15.24 mm length, with a weight of 2.195.
- 140G-H3I3-C25
Rockwell motor protection circuit breaker, model 140G-H3I3-C25. This device uses electronic protection and has a trip unit rating of 25 A. It is a molded case circuit breaker with an H-frame and three poles. The supplied data lists a current value of 125 A alongside the 25 A trip unit rating; these values are not reconciled here. Standards compliance is stated as UL489, CSA22.2 No. 5, and IEC 60947-2. The breaker is marked NOT_REPAIRABLE. Dimensions are 21.463 cm height, 14.859 cm width, and 13.462 cm length; weight is 1.744 KG. Stock status is NON_STOCKED, preferred availability is false, and quick turnaround is false.
- 140G-H3I3-D16
The Rockwell 140G-H3I3-D16 is a motor protection circuit breaker rated 160 A with electronic LSIG protection. Its IEC breaking capacity is 50 kA at 415 V, and its UL interrupting rating is 35 kA at 480 V. The unit is not repairable. Dimensions are 22.098 mm height, 14.732 mm width, and 13.589 mm length.
- 140G-H3X4
Product identification: ROCKWELL 140G-H3X4. The Allen Bradley 140G-H3X4 is a motor protection circuit breaker with a 125 A current rating and thermal magnetic or electronic protection. It is frame-only for adjustment. Certifications include UL Listed, CSA Certified, CE, and CCC. The device is not repairable. Dimensions are 13.299 in height, 14.801 in width, and 21.699 in length.
- 140G-H6C3-C15-AJ
The Rockwell 140G-H6C3-C15-AJ is a 3-pole motor protection circuit breaker with a 125 A frame and a thermal-magnetic trip unit. Rated permanent current Iu is 15 A, with thermal trip current Ir 15 A and magnetic trip current Im 400 A. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Per IEC 60947-2, rated ultimate short-circuit breaking capacity Icu is 70 kA at 500 V DC with 3 poles in series, thermal-magnetic trip unit only, and rated service short-circuit breaking capacity Ics is 100% Icu under the same conditions. Rated impulse withstand voltage Uimp is 8 kV, insulation voltage Ui is 1000 V per IEC, and watt loss is 3.4 W. The device measures 90 mm wide, 130 mm high, and 82.5 mm deep, with screw front connections and IP40 protection.