- 140G-H3H4-D16
The Rockwell 140G-H3H4-D16 is a four-pole motor protection circuit breaker with electronic LSI protection and a 160 A trip unit rating. It is not repairable. Dimensions are 22.225 mm height, 13.589 mm width, and 15.24 mm length, with a weight of 2.195.
- 140G-H3I3-C25
Rockwell motor protection circuit breaker, model 140G-H3I3-C25. This device uses electronic protection and has a trip unit rating of 25 A. It is a molded case circuit breaker with an H-frame and three poles. The supplied data lists a current value of 125 A alongside the 25 A trip unit rating; these values are not reconciled here. Standards compliance is stated as UL489, CSA22.2 No. 5, and IEC 60947-2. The breaker is marked NOT_REPAIRABLE. Dimensions are 21.463 cm height, 14.859 cm width, and 13.462 cm length; weight is 1.744 KG. Stock status is NON_STOCKED, preferred availability is false, and quick turnaround is false.
- 140G-H3I3-D16
The Rockwell 140G-H3I3-D16 is a motor protection circuit breaker rated 160 A with electronic LSIG protection. Its IEC breaking capacity is 50 kA at 415 V, and its UL interrupting rating is 35 kA at 480 V. The unit is not repairable. Dimensions are 22.098 mm height, 14.732 mm width, and 13.589 mm length.
- 140G-H3X4
Product identification: ROCKWELL 140G-H3X4. The Allen Bradley 140G-H3X4 is a motor protection circuit breaker with a 125 A current rating and thermal magnetic or electronic protection. It is frame-only for adjustment. Certifications include UL Listed, CSA Certified, CE, and CCC. The device is not repairable. Dimensions are 13.299 in height, 14.801 in width, and 21.699 in length.
- 140G-H6C3-C15-AJ
The Rockwell 140G-H6C3-C15-AJ is a 3-pole motor protection circuit breaker with a 125 A frame and a thermal-magnetic trip unit. Rated permanent current Iu is 15 A, with thermal trip current Ir 15 A and magnetic trip current Im 400 A. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Per IEC 60947-2, rated ultimate short-circuit breaking capacity Icu is 70 kA at 500 V DC with 3 poles in series, thermal-magnetic trip unit only, and rated service short-circuit breaking capacity Ics is 100% Icu under the same conditions. Rated impulse withstand voltage Uimp is 8 kV, insulation voltage Ui is 1000 V per IEC, and watt loss is 3.4 W. The device measures 90 mm wide, 130 mm high, and 82.5 mm deep, with screw front connections and IP40 protection.
- 140G-H6C3-C16
The Rockwell 140G-H6C3-C16 is a motor protection circuit breaker rated 125 A with thermal magnetic protection. It has a 65 kA interruption rating at 480V. Dimensions are 13.335 cm height, 15.24 cm width, and 21.615 cm length, with a weight of 1.633 kg. The device is not repairable.
- 140G-H6C3-C20
Rockwell motor protection circuit breaker, model 140G-H6C3-C20. Structured parameters list a trip unit rating of 20A and a current value of 125 A; these two figures are both supplied and are not reconciled here. The device is not repairable and is listed as non-stocked, with preferred availability and quick turnaround both marked false. Dimensions are 14.81 cm height, 13.31 cm width, and 21.69 cm length, with a weight of 1.651 KG. Lead time is stated as 5. No interrupting rating, certification, trip unit type, or pole count is confirmed by the authoritative data, so none is stated.
- 140G-H6C3-C20-AA
The Rockwell 140G-H6C3-C20-AA is a 3-pole motor protection circuit breaker with a rated permanent current of 20 A and a frame size of 125 A. It uses a fixed thermal/fixed magnetic trip unit, with thermal trip current of 20 A and magnetic trip current of 400 A. The interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 1000 V per IEC. The device measures 90 mm wide, 130 mm high, and 82.5 mm deep, with IP40 protection. Main circuit connections are front-side screw terminals. It is not suitable for direct DIN rail mounting, though DIN rail mounting is optional.