- 150-F317NBRB
The Rockwell 150-F317NBRB is an SMC Flex soft starter with an integrated LCD display and internal bypass. It is rated 317 A and 125–250 Hp at 460V AC, with a rated operating voltage of 200 V and control voltage of 24V AC/DC. The power circuit operates at 50/60 Hz, with line-connected motor current of 106–317 A at 600/Y/690V AC, 3-phase, and delta-connected motor current of 183–549 A at 500/575V AC, 3-phase. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is included. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high. Operating temperature is -5 to 50 °C open type.
- 150-F317NCD
The Rockwell 150-F317NCD is an SMC Flex soft starter rated 317 A and 125–250 Hp at 460 V AC. It operates on 3-phase, 50/60 Hz power with a rated operating voltage of 200 V and control voltage of 100...240 V AC. The controller includes a display, integrated motor overload protection, internal bypass, and status indication for stopped, starting, stopping, at speed, alarm, and fault. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. It is an open-type controller with IP2X protection (with terminal covers) per IEC for the power circuit. Operating temperature is -5 to 50 °C open. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F317NCDB
The Rockwell 150-F317NCDB is an SMC Flex soft starter rated 317 A and 125–250 Hp at 460V AC, with 200...600V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit and 100...240V AC control voltage. It has an integrated display, internal bypass, integrated motor overload protection, and trip classes 10, 15, 20, and 30. Line-connected motor current is 106...317 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 183...549 A at 500/575V AC, 3-phase. Operating temperature is -5 to 50 °C open type, humidity 5...95% noncondensing, altitude 2000 m. Dimensions are 290 mm width, 276.5 mm depth, 600 mm height.
- 150-F317NZDB
Product identification: ROCKWELL 150-F317NZDB. The Allen-Bradley 150-F317NZDB is an SMC Flex soft starter with an integrated display. It is rated 317 A and 125–250 hp at 460 V AC, with a control voltage of 100...240 V AC. Overload current is 106 A for line-connected devices and 183 A for delta-connected devices. Control options include pump control.
- 150-F361NBD
The Rockwell 150-F361NBD is an SMC Flex soft starter with a 361 A controller rating, rated 150–300 Hp at 460 V AC. It has a 200–480 V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit, 50/60 Hz operating frequency, and 200–480 V AC input. Control voltage is 100–240 V AC. It includes a display, integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30. Line-connected motor current is 120–361 A at 600/Y/690 V AC, 3-phase; delta-connected motor current is 208–625 A at 500/575 V AC, 3-phase. The open-type enclosure measures 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F361NBDD
The Rockwell 150-F361NBDD is an SMC Flex soft starter with a 361 A controller rating and 150–300 Hp at 460 V AC. The rated operating voltage Ue is 200 V, and control voltage is 100...240 V AC. It includes a display and supports brake control. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor full-load current. Overload current is 120 A for line-connected devices and 208 A for delta-connected devices. The power circuit uses an RC snubber network for DV/DT protection, operates at 50/60 Hz, and has a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA. Maximum line-connected motor power is 450 Hp at 600 V AC, 60 Hz, three-phase.
- 150-F361NCDB
The Rockwell 150-F361NCDB is an SMC Flex soft starter with a 361 A controller rating, rated 150–300 Hp at 460V AC. It operates on three-phase power at 50/60 Hz with a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA. Control voltage is 100...240V AC. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current at 117% of motor FLC. Line-connected motor current is 120...361 A at 600/Y/690V AC; delta-connected motor current is 208...625A at 500/575V AC. The open-type unit has an internal bypass, a display, and IP2X protection with terminal covers per IEC. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F361NCRB
The Rockwell 150-F361NCRB is an SMC Flex soft starter with a 361 A controller rating for 150–300 Hp at 460 V AC. It operates on 200–600 V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, three-phase, with 24 V AC/DC control. Line-connected motor current is 120–361 A at 600/Y/690 V AC; delta-connected current is 208–625 A at 500/575 V AC. Integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30 are included. The open-type enclosure measures 290 mm wide, 276.5 mm deep, and 600 mm high, with an operating temperature of -5 to 50 °C (23 to 122 °F).